Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1G3UM

1G3UM

Altech Corporation

CIR BRKR THRM-MAG 3A LEVER

0

2CU4L

2CU4L

Altech Corporation

2CU4L4.0A MCBCCHAR2P 480Y/277VAC

12

3DU2L

3DU2L

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

1132

2DU15R

2DU15R

Altech Corporation

2DU15R15A MCBDCHAR2P 480Y/277VAC

61162

1E15UM

1E15UM

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

924

2G2UM

2G2UM

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

12

3CU30L

3CU30L

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

412

1D30UL

1D30UL

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

2460

2D15UL

2D15UL

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

0

2C20UL

2C20UL

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

54

1D15UL

1D15UL

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

23420

3E10UM

3E10UM

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

7

2BU16R

2BU16R

Altech Corporation

2BU16R 16A MCBBCHAR2P 480Y/277VA

678

1C2UL

1C2UL

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

29

2BU40R

2BU40R

Altech Corporation

2BU40R 40A MCBBCHAR2P 480Y/277VA

2

3D15UL

3D15UL

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

49

2CU15R

2CU15R

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

3466

3D20UL

3D20UL

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

1752

1CU5L

1CU5L

Altech Corporation

CIR BRKR THRM-MAG 50A LEVER

46228

2CU30L

2CU30L

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

3454

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure