Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1C10UL

1C10UL

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

58

2DU6L

2DU6L

Altech Corporation

2DU6L6.0A MCBDCHAR2P 480Y/277VAC

0

2CU10L

2CU10L

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

3

2DU30L

2DU30L

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

866

3D50UM

3D50UM

Altech Corporation

CIR BRKR THRM-MAG 50A LEVER

1348

1DU3L

1DU3L

Altech Corporation

CIR BRKR THRM-MAG 3A LEVER

6496

1DU5L

1DU5L

Altech Corporation

CIR BRKR THRM-MAG 5A LEVER

16204

2B2UR

2B2UR

Altech Corporation

2B2UR 2A MCB B CHAR 2 P 480Y/277

176

2G20UM

2G20UM

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

1112

2G16UM

2G16UM

Altech Corporation

CIR BRKR THRM-MAG 16A LEVER

10

2CU50R

2CU50R

Altech Corporation

2CU50R 50A MCBCCHAR2P 480Y/277VA

6

1D2UM

1D2UM

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

28

3DU15L

3DU15L

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

8212

2D20UL

2D20UL

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

496

3D10UM

3D10UM

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

15

3D15UM

3D15UM

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

1344

1CU2L

1CU2L

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

15156

2D2UM

2D2UM

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

16

3C40UL

3C40UL

Altech Corporation

CIR BRKR THRM-MAG 40A LEVER

21

1D3UL

1D3UL

Altech Corporation

CIR BRKR THRM-MAG 3A LEVER

2284

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top