Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1C15UL

1C15UL

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

8672

1G2UM

1G2UM

Altech Corporation

1G2UM 2A CIRCUIT BREAKER G CHAR

4

1CU2R

1CU2R

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

28216

2D15UM

2D15UM

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

0

2D6UM

2D6UM

Altech Corporation

CIR BRKR THRM-MAG 6A LEVER

51

2D3UM

2D3UM

Altech Corporation

CIR BRKR THRM-MAG 3A LEVER

7168

3DU15R

3DU15R

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

23

3DU10R

3DU10R

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

44

1C3UL

1C3UL

Altech Corporation

CIR BRKR THRM-MAG 3A LEVER

11168

1D16UM

1D16UM

Altech Corporation

CIR BRKR THRM-MAG 16A LEVER

14

2DU15L

2DU15L

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

12

1G5UM

1G5UM

Altech Corporation

1G5UM 5A CIRCUIT BREAKER G CHAR

15

2CU63L

2CU63L

Altech Corporation

2CU63L63A MCBCCHAR2P 240V ACUL48

4

1D5UL

1D5UL

Altech Corporation

CIR BRKR THRM-MAG 5A LEVER

16

2D30UM

2D30UM

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

66

GFR4C30100

GFR4C30100

Altech Corporation

EGFP+OL 30A480Y277V AC 100MA C T

2

3C60UL

3C60UL

Altech Corporation

CIR BRKR THRM-MAG 60A LEVER

0

1BU16R

1BU16R

Altech Corporation

CIR BRKR THRM-MAG 16A LEVER

4524

3C15UL

3C15UL

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

3

2D1UM

2D1UM

Altech Corporation

2D1UM 1A CIRCUIT BREAKER D CHAR2

24

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top