Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1CU15L

1CU15L

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

2348

2DU2R

2DU2R

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

18108

2DU10L

2DU10L

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

3048

2C16UL

2C16UL

Altech Corporation

CIR BRKR THRM-MAG 16A LEVER

16718

1DU2L

1DU2L

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

85

1B6UM

1B6UM

Altech Corporation

CIR BRKR THRM-MAG 6A LEVER

0

1CU10R

1CU10R

Altech Corporation

1CU10R 10A MCB C CHAR 1 P 277VAC

343240

1C2UM

1C2UM

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

6

3DU6R

3DU6R

Altech Corporation

3DU6R 6AMCBDCHAR3P 480Y/277VACUL

20

1CU10L

1CU10L

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

13480

1C4UL

1C4UL

Altech Corporation

CIR BRKR THRM-MAG 4A LEVER

5180

1DU5R

1DU5R

Altech Corporation

CIR BRKR THRM-MAG 5A LEVER

912

3C20UL

3C20UL

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

8

1CU5R

1CU5R

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

27228

1C3UM

1C3UM

Altech Corporation

CIR BRKR THRM-MAG 3A LEVER

36

MMS-32H-1.6A

MMS-32H-1.6A

Altech Corporation

MANUAL MOTOR START 65KA 1-16A

3

3D60UM

3D60UM

Altech Corporation

CIR BRKR THRM-MAG 60A LEVER

134

2D30UL

2D30UL

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

90144

1G4UM

1G4UM

Altech Corporation

1G4UM 4A CIRCUIT BREAKER G CHAR

43120

2D16UM

2D16UM

Altech Corporation

CIR BRKR THRM-MAG 16A LEVER

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure