Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
2CU6L

2CU6L

Altech Corporation

2CU6L6.0A MCBCCHAR2P 480Y/277VAC

106

1E3UM

1E3UM

Altech Corporation

1E3UM 3ACIRCUIT BREAKER 3 CHAR 1

48432

MMS-32H-6A

MMS-32H-6A

Altech Corporation

MANUAL MOTOR START 65KA 4-6A

0

2C6UL

2C6UL

Altech Corporation

CIR BRKR THRM-MAG 6A LEVER

86

1BU10R

1BU10R

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

4884

1BU5R

1BU5R

Altech Corporation

CIR BRKR THRM-MAG 5A LEVER

1172240

1CU15R

1CU15R

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

41132

3D40UM

3D40UM

Altech Corporation

CIR BRKR THRM-MAG 40A LEVER

320

3G30UM

3G30UM

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

412

2DU4L

2DU4L

Altech Corporation

2DU4L4.0A MCBDCHAR2P 480Y/277VAC

412

3DU40R

3DU40R

Altech Corporation

CIR BRKR THRM-MAG 40A LEVER

224172

3G10UM

3G10UM

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

832

2CU5L

2CU5L

Altech Corporation

CIR BRKR THRM-MAG 5A LEVER

11

2DU6R

2DU6R

Altech Corporation

CIR BRKR THRM-MAG 6A LEVER

22402

3D10UL

3D10UL

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

1312

GFR4C20100

GFR4C20100

Altech Corporation

EGFP+OL 20A480Y277V AC 100MA C T

2

3C3UL

3C3UL

Altech Corporation

CIR BRKR THRM-MAG 3A LEVER

24

MS016

MS016

Altech Corporation

MS016 MANUAL MOTOR CONTROLLER 01

5

1CU1L

1CU1L

Altech Corporation

CIR BRKR THRM-MAG 1A LEVER

50144

2CU20L

2CU20L

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

126

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email