Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
3DU30L

3DU30L

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

12

1DU3R

1DU3R

Altech Corporation

CIR BRKR THRM-MAG 3A LEVER

2448

3CU25L

3CU25L

Altech Corporation

CIR BRKR THRM-MAG 25A LEVER

1048

1G15UM

1G15UM

Altech Corporation

1G15UM 15A CIRCUIT BREAKER G CHA

108

MMS-32H-22A

MMS-32H-22A

Altech Corporation

MANUAL MOTOR START 30KA 14-22A

0

3G20UM

3G20UM

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

824

2DU2L

2DU2L

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

71

2C50UL

2C50UL

Altech Corporation

CIR BRKR THRM-MAG 50A LEVER

18

3CU30R

3CU30R

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

1324

2C15UL

2C15UL

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

724

2D10UL

2D10UL

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

12

2D1.6UM

2D1.6UM

Altech Corporation

CIR BRKR THRM-MAG 1.6A LEVER

1048

GFL2B200102

GFL2B200102

Altech Corporation

MCCB+EGFP 20A240V AC 10MA B TRIP

76

2G5UM

2G5UM

Altech Corporation

CIR BRKR THRM-MAG 5A LEVER

19

2D4UM

2D4UM

Altech Corporation

CIR BRKR THRM-MAG 4A LEVER

3

2D4UL

2D4UL

Altech Corporation

CIR BRKR THRM-MAG 4A LEVER

29

2C25UL

2C25UL

Altech Corporation

CIR BRKR THRM-MAG 25A LEVER

22

2DU5L

2DU5L

Altech Corporation

CIR BRKR THRM-MAG 5A LEVER

0

3C30UL

3C30UL

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

0

3DU20R

3DU20R

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure