Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
DC1CU05L

DC1CU05L

Altech Corporation

DC1CU05L05A MCB C CHAR 1P125VDCU

0

2D13UL

2D13UL

Altech Corporation

2D13UL 13A CIRCUIT BREAKER D CHA

6

GFL2B40030SN

GFL2B40030SN

Altech Corporation

MCCB+EGFP 40A120240V AC 30MA B T

0

2E10UM

2E10UM

Altech Corporation

2E10UM 10A CIRCUIT BREAKER E CHA

18

3D6UL

3D6UL

Altech Corporation

3D6UL 6A CIRCUIT BREAKER D CHAR3

0

MA040UM

MA040UM

Altech Corporation

MA040UM 025-040A 3P MOTORPROTECT

0

MA25UM

MA25UM

Altech Corporation

MA25UM 20-25A 3P MOTORPROTECTOR

36

GFR2B15300

GFR2B15300

Altech Corporation

EGFP+OL 15A277V AC 300MA B TRIP

0

3B60UR

3B60UR

Altech Corporation

CIRCUIT BREAKER60UR 60A MCB B CH

0

GFR4B06030

GFR4B06030

Altech Corporation

EGFP+OL 6A480Y277V AC 30MA B TRI

0

GFR2C05030

GFR2C05030

Altech Corporation

EGFP+OL 5A277V AC 30MA C TRIP 1P

2

UV12ACL

UV12ACL

Altech Corporation

CIRCUIT BREAK UNDERVOLT 12VAC

0

GFL2B16100S

GFL2B16100S

Altech Corporation

MCCB+EGFP 16A120240V AC 100MA B

0

1BU4R

1BU4R

Altech Corporation

1BU4R 4A MCB B CHAR 1P277VACUL10

96

1B12UR

1B12UR

Altech Corporation

1B12UR 12A MCB B CHAR 1 P 277VAC

0

1E10UM

1E10UM

Altech Corporation

1E10UM 10ACIRCUIT BREAKER 3 CHAR

0

DC2CU63L

DC2CU63L

Altech Corporation

DC2CU63L63A MCB CCHAR 2P 250VDC

6

GFR4B20100

GFR4B20100

Altech Corporation

EGFP+OL 20A480Y277V AC 100MA B T

0

1B20UM

1B20UM

Altech Corporation

1B20UM 20A CIRCUIT BREAKER B CHA

24

3C4UR

3C4UR

Altech Corporation

3C4UR 4A MCB C CHAR 3 P 480Y/277

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email