Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GFR4C08030

GFR4C08030

Altech Corporation

EGFP+OL 8A480Y277V AC 30MA C TRI

0

1D4UR

1D4UR

Altech Corporation

1D4UR 4A MCB D CHAR 1 P 277VAC U

0

GFR2B08300

GFR2B08300

Altech Corporation

EGFP+OL 8A277V AC 300MA B TRIP 1

0

GFL2B25100SN

GFL2B25100SN

Altech Corporation

MCCB+EGFP 25A120240V AC 100MA B

0

1ZU5L

1ZU5L

Altech Corporation

1ZU5L5A MCB Z CHAR 1P277VACUL489

0

2D50DL

2D50DL

Altech Corporation

2D50DL 50A CIRCUIT BREAKER D CHA

0

1DU12L

1DU12L

Altech Corporation

1DU12L 12A MCB D CHAR 1P277VACUL

0

3D5UL

3D5UL

Altech Corporation

3D5UL 5A CIRCUIT BREAKER D CHAR3

52

3BU60R

3BU60R

Altech Corporation

3BU60R60AMCBBCHAR3P 480Y/277VACU

0

2DU25R

2DU25R

Altech Corporation

2DU25R25A MCBDCHAR2P 480Y/277VAC

108

3B13UM

3B13UM

Altech Corporation

CIRCUIT BREAKER 13A B 3P 277V UL

0

GFL2B16300SN

GFL2B16300SN

Altech Corporation

MCCB+EGFP 16A120240V AC 300MA B

0

2Z30UL

2Z30UL

Altech Corporation

2Z30UL 30A CIRCUIT BREAKER Z CHA

0

GFL2C30300S

GFL2C30300S

Altech Corporation

MCCB+EGFP 30A120240V AC 300MA C

6

2D03DL

2D03DL

Altech Corporation

2D03DL 0.3A CIRCUIT BREAKER D CH

0

MA025UM

MA025UM

Altech Corporation

MA025UM 016-025A 3P MOTORPROTECT

0

GFL2C080302

GFL2C080302

Altech Corporation

MCCB+EGFP 8A240V AC 30MA C TRIP

18

GFL2D13030SN

GFL2D13030SN

Altech Corporation

MCCB+EGFP 13A120240V AC 30MA D T

0

2Z03UM

2Z03UM

Altech Corporation

2Z03UM 0.3A CIRCUIT BREAKER Z CH

0

2C13UR

2C13UR

Altech Corporation

2C13UR 13A MCB C CHAR 2 P 480Y/2

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure