Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GFL2B05100S

GFL2B05100S

Altech Corporation

MCCB+EGFP 5A120240V AC 100MA B T

0

GFL2C150102

GFL2C150102

Altech Corporation

MCCB+EGFP 15A240V AC 10MA C TRIP

12

1D4DL

1D4DL

Altech Corporation

1D4DL 4A CIRCUIT BREAKER D CHAR

0

GFR4C25030

GFR4C25030

Altech Corporation

EGFP+OL 25A480Y277V AC 30MA C TR

0

3E3UM

3E3UM

Altech Corporation

3E3UM 3A CIRCUIT BREAKER ECHAR3P

8

GFR2C12100

GFR2C12100

Altech Corporation

EGFP+OL 12A277V AC 100MA C TRIP

0

MMS-100H-75A

MMS-100H-75A

Altech Corporation

MANUAL MOTOR START 50KA 55-75A

0

2C03DL

2C03DL

Altech Corporation

2C03DL 0.3A CIRCUIT BREAKER C CH

0

3Z25UM

3Z25UM

Altech Corporation

3Z25UM 25A CIRCUIT BREAKER Z CHA

0

3E1.6UM

3E1.6UM

Altech Corporation

3E1.6UM 1.6A CIRCUIT BREAKER ECH

0

2CU2L

2CU2L

Altech Corporation

2CU2L2.0A MCBCCHAR2P 480Y/277VAC

0

1CU63L

1CU63L

Altech Corporation

1CU63L63A MCB C CHAR 1P240VACUL4

0

UM-6R

UM-6R

Altech Corporation

REMOTE RESET 600MM OVERLOAD RELA

0

GFR2B40100

GFR2B40100

Altech Corporation

EGFP+OL 40A277V AC 100MA B TRIP

5

2D25UL

2D25UL

Altech Corporation

2D25UL 25A CIRCUIT BREAKER D CHA

0

GFL2D08100S

GFL2D08100S

Altech Corporation

MCCB+EGFP 8A120240V AC 100MA D T

0

1D30DL

1D30DL

Altech Corporation

1D30DL 30A CIRCUIT BREAKER D CHA

24

3DU60R

3DU60R

Altech Corporation

3DU60R 60AMCBDCHAR3P 480Y/277VAC

0

GFR2D25300

GFR2D25300

Altech Corporation

EGFP+OL 25A277V AC 300MA D TRIP

0

1C13UL

1C13UL

Altech Corporation

1C13UL 13A CIRCUIT BREAKER C CHA

24

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure