Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1D10UL

1D10UL

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

0

3D20UM

3D20UM

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

12316

MMS-32H-40A

MMS-32H-40A

Altech Corporation

MANUAL MOTOR START 30KA 28-40A

2

1DU10R

1DU10R

Altech Corporation

1DU10R10A MCB D CHAR 1P277VACUL1

108

GFL2C200302

GFL2C200302

Altech Corporation

MCCB+EGFP 20A240V AC 30MA C TRIP

47

2DU20L

2DU20L

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

24

1C5UR

1C5UR

Altech Corporation

1C5UR 5A MCB C CHAR 1 P 277VAC U

30

1D10UM

1D10UM

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

40

2C10UL

2C10UL

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

26

3BU32R

3BU32R

Altech Corporation

3BU32R32AMCBBCHAR3P 480Y/277VACU

28

2DU40L

2DU40L

Altech Corporation

CIR BRKR THRM-MAG 40A LEVER

2342

1BU3R

1BU3R

Altech Corporation

CIR BRKR THRM-MAG 3A LEVER

39360

1CU3L

1CU3L

Altech Corporation

CIR BRKR THRM-MAG 3A LEVER

31288

2DU25L

2DU25L

Altech Corporation

CIR BRKR THRM-MAG 25A LEVER

136

GFR2B06100

GFR2B06100

Altech Corporation

EGFP+OL 6A277V AC 100MA B TRIP 1

0

GFL2C10010S

GFL2C10010S

Altech Corporation

MCCB+EGFP 10A120240V AC 10MA C T

6

2CU10R

2CU10R

Altech Corporation

2CU10R 10A MCBCCHAR2P 480Y/277VA

18

GFR4D40100

GFR4D40100

Altech Corporation

EGFP+OL 40A480Y277V AC 100MA D T

0

GFR4D15030

GFR4D15030

Altech Corporation

EGFP+OL 15A480Y277V AC 30MA D TR

2

GFL2D06100S

GFL2D06100S

Altech Corporation

MCCB+EGFP 6A120240V AC 100MA D T

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure