Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
2CU15L

2CU15L

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

966

1D2UL

1D2UL

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

9240

2C30UL

2C30UL

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

1418

1D8UM

1D8UM

Altech Corporation

CIR BRKR THRM-MAG 8A LEVER

93

2D10UM

2D10UM

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

11114

3D40UL

3D40UL

Altech Corporation

CIR BRKR THRM-MAG 40A LEVER

0

MMS-32H-13A

MMS-32H-13A

Altech Corporation

MANUAL MOTOR START 65KA 9-13A

3

1DU15L

1DU15L

Altech Corporation

CIR BRKR THRM-MAG 15A LEVER

4156

1DU20L

1DU20L

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

19144

3DU20L

3DU20L

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

372

1D20UM

1D20UM

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

19

2D5UL

2D5UL

Altech Corporation

CIR BRKR THRM-MAG 5A LEVER

254

1D4UM

1D4UM

Altech Corporation

CIR BRKR THRM-MAG 4A LEVER

512

3CU20L

3CU20L

Altech Corporation

CIR BRKR THRM-MAG 20A LEVER

1732

3D30UL

3D30UL

Altech Corporation

CIR BRKR THRM-MAG 30A LEVER

72

1BU2R

1BU2R

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

12

3D2UL

3D2UL

Altech Corporation

CIR BRKR THRM-MAG 2A LEVER

3324

1DU10L

1DU10L

Altech Corporation

CIR BRKR THRM-MAG 10A LEVER

358192

2DU50L

2DU50L

Altech Corporation

CIR BRKR THRM-MAG 50A LEVER

942

2C40UL

2C40UL

Altech Corporation

CIR BRKR THRM-MAG 40A LEVER

66

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure