Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
2CU05R

2CU05R

Altech Corporation

2CU05R0.5A MCBCCHAR2P 480Y/277VA

0

GFR4D12030

GFR4D12030

Altech Corporation

EGFP+OL 12A480Y277V AC 30MA D TR

0

2G125UM

2G125UM

Altech Corporation

2G125UM 12.5ACIRCUIT BREAKER G C

0

UV24DCL

UV24DCL

Altech Corporation

CIRCUIT BREAK UNDERVOLT 24V DC C

0

1C15UR

1C15UR

Altech Corporation

1C15UR 15A MCB C CHAR 1 P 277VAC

0

3DU3R

3DU3R

Altech Corporation

3DU3R 3AMCBDCHAR3P 480Y/277VACUL

80

GFL2D12300S

GFL2D12300S

Altech Corporation

MCCB+EGFP 12A120240V AC 300MA D

0

3CU3L

3CU3L

Altech Corporation

3CU3L3.0AMCBCCHAR3P 480Y/277VACU

120

2BU10R

2BU10R

Altech Corporation

2BU10R 10A MCBBCHAR2P 480Y/277VA

12

GFL2D100102

GFL2D100102

Altech Corporation

MCCB+EGFP 10A240V AC 10MA D TRIP

0

GFR2B16100

GFR2B16100

Altech Corporation

EGFP+OL 16A277V AC 100MA B TRIP

0

2B5UM

2B5UM

Altech Corporation

2B5UM 5A CIRCUIT BREAKER B CHAR2

12

GFR2D15300

GFR2D15300

Altech Corporation

EGFP+OL 15A277V AC 300MA D TRIP

0

GFL2D25300SN

GFL2D25300SN

Altech Corporation

MCCB+EGFP 25A120240V AC 300MA D

0

2Z5UM

2Z5UM

Altech Corporation

2Z5UM 5A CIRCUIT BREAKER Z CHAR2

0

GFR2C08010

GFR2C08010

Altech Corporation

EGFP+OL 8A277V AC 10MA C TRIP 1P

0

3BU1R

3BU1R

Altech Corporation

3BU1R1AMCBBCHAR3P 480Y/277VACUL1

0

2B16UR

2B16UR

Altech Corporation

2B16UR 16A MCB B CHAR 2 P 480Y/2

60

GFL2D32100S

GFL2D32100S

Altech Corporation

MCCB+EGFP 32A120240V AC 100MA D

0

1DU13L

1DU13L

Altech Corporation

1DU13L 13A MCB D CHAR 1P277VACUL

24

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure