Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
3CU16R

3CU16R

Altech Corporation

3CU16R16AMCBCCHAR3P 480Y/277VACU

8

GFL2C06300SN

GFL2C06300SN

Altech Corporation

MCCB+EGFP 6A120240V AC 300MA C T

0

1BU30R

1BU30R

Altech Corporation

1BU30R 30A MCB B CHAR 1P277VACUL

60

3B5UM

3B5UM

Altech Corporation

CIRCUIT BREAKER5UM 5A B CHAR3P48

0

1D13UR

1D13UR

Altech Corporation

1D13UR 13A MCB D CHAR 1 P 277VAC

0

GFR2C20030

GFR2C20030

Altech Corporation

EGFP+OL 20A277V AC 30MA C TRIP 1

52

GFR4C10030

GFR4C10030

Altech Corporation

EGFP+OL 10A480Y277V AC 30MA C TR

0

GFR2B13300

GFR2B13300

Altech Corporation

EGFP+OL 13A277V AC 300MA B TRIP

0

MMS-100H-90A

MMS-100H-90A

Altech Corporation

MANUAL MOTOR START 50KA 70-90A

0

GFL2D25100S

GFL2D25100S

Altech Corporation

MCCB+EGFP 25A120240V AC 100MA D

0

2Z4UM

2Z4UM

Altech Corporation

2Z4UM 4A CIRCUIT BREAKER Z CHAR2

18

2B16UM

2B16UM

Altech Corporation

2B16UM 16A CIRCUIT BREAKER B CHA

0

2CU60L

2CU60L

Altech Corporation

2CU60L60A MCBCCHAR2P 240V ACUL48

6

UTS250N-FTU-225

UTS250N-FTU-225

Altech Corporation

CIRCUIT BREAKER 225A/480V AC 3P

0

GFL2B16030S

GFL2B16030S

Altech Corporation

MCCB+EGFP 16A120240V AC 30MA B T

0

1D6UM

1D6UM

Altech Corporation

1D6UM 6A CIRCUIT BREAKER D CHAR

0

GFR4D25030

GFR4D25030

Altech Corporation

EGFP+OL 25A480Y277V AC 30MA D TR

0

GFL2C12100SN

GFL2C12100SN

Altech Corporation

MCCB+EGFP 12A120240V AC 100MA C

6

3C50UM

3C50UM

Altech Corporation

3C50UM 50ACIRCUIT BREAKER C CHAR

0

3C13UL

3C13UL

Altech Corporation

3C13UL 13A CIRCUIT BREAKER C CHA

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure