Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
TR11-C-X-63-B-0-C-2.5A

TR11-C-X-63-B-0-C-2.5A

Altech Corporation

CIRCUIT BREAK BLK SLIDERNOTBHEX

30

2C6UM

2C6UM

Altech Corporation

2C6UM 6A CIRCUIT BREAKER C CHAR2

6

2E32UM

2E32UM

Altech Corporation

2E32UM 32A CIRCUIT BREAKER E CHA

36

GFL2C083002

GFL2C083002

Altech Corporation

MCCB+EGFP 8A240V AC 300MA C TRIP

0

3DU13L

3DU13L

Altech Corporation

3DU13L13AMCBDCHAR3P 480Y/277VACU

0

GFR4D20300

GFR4D20300

Altech Corporation

EGFP+OL 20A480Y277V AC 300MA D T

0

1BU05R

1BU05R

Altech Corporation

1BU05R0.5A MCB B CHAR 1P277VACUL

96

GFL2D06010S

GFL2D06010S

Altech Corporation

MCCB+EGFP 6A120240V AC 10MA D TR

0

1Z08UM

1Z08UM

Altech Corporation

1Z08UM 0.8A CIRCUIT BREAKER Z CH

0

MMS-63H-65A

MMS-63H-65A

Altech Corporation

MANUAL MOTOR START 50KA 47-65A

0

GFL2B161002

GFL2B161002

Altech Corporation

MCCB+EGFP 16A240V AC 100MA B TRI

0

GF425030

GF425030

Altech Corporation

EGFP 25A480Y277V AC 30MA 3P+N 50

11

3D05UM

3D05UM

Altech Corporation

3D05UM 0.5A CIRCUIT BREAKER D CH

16

GFR4D13030

GFR4D13030

Altech Corporation

EGFP+OL 13A480Y277V AC 30MA D TR

0

1G40UM

1G40UM

Altech Corporation

1G40UM 40A CIRCUIT BREAKER G CHA

0

2B8UR

2B8UR

Altech Corporation

2B8UR 8A MCB B CHAR 2 P 480Y/277

12

GFL2C16010SN

GFL2C16010SN

Altech Corporation

MCCB+EGFP 16A120240V AC 10MA C T

0

GFL2B160102

GFL2B160102

Altech Corporation

MCCB+EGFP 16A240V AC 10MA B TRIP

0

1BU40R

1BU40R

Altech Corporation

1BU40R 40A MCB B CHAR 1P277VACUL

0

1G50UM

1G50UM

Altech Corporation

1G50UM 50A CIRCUIT BREAKER G CHA

468

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure