Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GFL2C40100S

GFL2C40100S

Altech Corporation

MCCB+EGFP 40A120240V AC 100MA C

0

GFR2B15100

GFR2B15100

Altech Corporation

EGFP+OL 15A277V AC 100MA B TRIP

5

GF240100

GF240100

Altech Corporation

EGFP 40A277V AC 100MA 1P+N 5060H

77

1D63UL

1D63UL

Altech Corporation

1D63UL 63A CIRCUIT BREAKER D CHA

0

1E40UM

1E40UM

Altech Corporation

1E40UM 40ACIRCUIT BREAKER E CHAR

12

1C13UR

1C13UR

Altech Corporation

1C13UR 13A MCB C CHAR 1 P 277VAC

36

18.46303/AC

18.46303/AC

Altech Corporation

FI-DFS4 63A30MA230/400VAC 4P ELC

10

2BU60R

2BU60R

Altech Corporation

2BU60R 60A MCBBCHAR2P 480Y/277VA

0

DC2DU13L

DC2DU13L

Altech Corporation

DC2DU13L13A MCBDCHAR 2P250VDCUL4

0

3B30UM

3B30UM

Altech Corporation

CIRCUIT BREAKER30UM 30A B CHAR3P

0

1E25UM

1E25UM

Altech Corporation

1E25UM 25ACIRCUIT BREAKER E CHAR

0

2D60UM

2D60UM

Altech Corporation

2D60UM 60A CIRCUIT BREAKER D CHA

0

1C8UL

1C8UL

Altech Corporation

1C8UL 8A CIRCUIT BREAKER C CHAR

168

GFR4C05030

GFR4C05030

Altech Corporation

EGFP+OL 5A480Y277V AC 30MA C TRI

0

GFL2B08010SN

GFL2B08010SN

Altech Corporation

MCCB+EGFP 8A120240V AC 10MA B TR

0

1DU30R

1DU30R

Altech Corporation

1DU30R30A MCB D CHAR 1P277VACUL1

24

3D1.6UM

3D1.6UM

Altech Corporation

3D1.6UM 1.6ACIRCUIT BREAKER D CH

4

GFR2D32100

GFR2D32100

Altech Corporation

EGFP+OL 32A277V AC 100MA D TRIP

0

3DU30R

3DU30R

Altech Corporation

3DU30R 30AMCBDCHAR3P 480Y/277VAC

168

1C1.6UL

1C1.6UL

Altech Corporation

1C1.6UL 1.6A CIRCUIT BREAKER C C

12

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure