Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9104173500

9104173500

Weidmuller

CIR BRKR 100MA 250VAC 80VDC

54

BR1D13UC

BR1D13UC

Weidmuller

CB MCB 489 1P D 13A ACDC

109

SU3D8UC

SU3D8UC

Weidmuller

CB PROTECTOR 1077 3P D 8A ACDC

56

SU3C16UC

SU3C16UC

Weidmuller

CB PROTECTOR 1077 3P C 16A ACDC

31

9911081302

9911081302

Weidmuller

CB2211-10 W/O AUX T1 0.8A

0

SU2C7UC

SU2C7UC

Weidmuller

CB PROTECTOR 1077 2P C 7A ACDC

47

1278730000

1278730000

Weidmuller

CIRCUIT BREAKER THRM 3A 28VDC

0

9911301205

9911301205

Weidmuller

2210-T210-KOM3-H121-3A

0

9912801302

9912801302

Weidmuller

CB2212-10 W/O AUX T1 8.0A

0

BR1C63UC

BR1C63UC

Weidmuller

CB MCB 489 1P C 63A ACDC

156

9911501300

9911501300

Weidmuller

CB2211-10 5.0A W/NO AUX CONT

0

9911501102

9911501102

Weidmuller

CB 2211-10 W/O AUXILIARY

0

BR3D7UC

BR3D7UC

Weidmuller

CB MCB 489 3P D 7A ACDC

40

9912150003

9912150003

Weidmuller

CIR BRKR 1.5A 480VAC 65VDC

0

9926251215

9926251215

Weidmuller

QL-1-13-DM-1-15

0

9926261904

9926261904

Weidmuller

QY-A-1-13-DM-U2-04

0

9926281510

9926281510

Weidmuller

CIR BRKR MAG-HYDR 10A 240VAC

0

BR3C8UC

BR3C8UC

Weidmuller

CB MCB 489 3P C 8A ACDC

28

9921151105

9921151105

Weidmuller

CIRCUIT BREAKER 15A

0

9921151302

9921151302

Weidmuller

CB2211-10 T2 W/O AUX 15A

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure