Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
BR2C50UC

BR2C50UC

Weidmuller

CB MCB 489 2P C 50A ACDC

91

9926261010

9926261010

Weidmuller

CIR BRKR MAG-HYDR 10A 120VAC

0

9911301105

9911301105

Weidmuller

CB2211-10 W/NO AUX. 3A FAST

0

9974421902

9974421902

Weidmuller

CBH8342-10 25A W/O AUX

0

9920161205

9920161205

Weidmuller

2210-T220-K0M3-H121-16A

0

SU1D50UC

SU1D50UC

Weidmuller

CB PROTECTOR 1077 1P D 50A ACDC

12

BR2C63UC

BR2C63UC

Weidmuller

CB MCB 489 2P C 63A ACDC

81

9926252940

9926252940

Weidmuller

QY-2-13-DM-U2-40

0

SU2D63UC

SU2D63UC

Weidmuller

CB PROTECTOR 1077 2P D 63A ACDC

21

9911801105

9911801105

Weidmuller

CIRCUIT BREAKER 8A

0

9926241305

9926241305

Weidmuller

QL-1-13-D-9-05

0

9107843200

9107843200

Weidmuller

CIR BRKR 12A 250VAC 80VDC

0

9911800002

9911800002

Weidmuller

CB2211 8AM W/O AUX. CONTACT

0

9913040003

9913040003

Weidmuller

CIR BRKR 400MA 480VAC 65VDC

0

9926261505

9926261505

Weidmuller

CIR BRKR MAG-HYDR 5A 240VAC

0

9922320003

9922320003

Weidmuller

2210-T220-KOM1-H1A1-32A

0

9911061302

9911061302

Weidmuller

CB2211-10 W/O AUX T1 0.6A

0

9926252950

9926252950

Weidmuller

QY-2-13-DM-2-50

0

9926283505

9926283505

Weidmuller

CIR BRKR MAG-HYDR 5A 480VAC

0

9922161302

9922161302

Weidmuller

CB2212-10 W/O AUX T1 16A

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure