Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9124193500

9124193500

Weidmuller

CIR BRKR 13A 250VAC 80VDC

0

9913010003

9913010003

Weidmuller

CIR BRKR 100MA 480VAC 65VDC

0

9926271001

9926271001

Weidmuller

CIR BRKR MAG-HYDR 1A 120VAC

0

9923101302

9923101302

Weidmuller

CB2213-10 W/O AUX.CONTACTS 10A

0

9922121302

9922121302

Weidmuller

CB2210-10 T1 W/O AUX 12A

0

9913011302

9913011302

Weidmuller

CB2213-10 W/O AUX T1 0.1A

0

9926253535

9926253535

Weidmuller

QZ-3-13-D-2-35

0

9912801309

9912801309

Weidmuller

CB2212-10 W/N/O AUX 8A TD

0

9124263500

9124263500

Weidmuller

CIR BRKR 300MA 250VAC 80VDC

0

9926281520

9926281520

Weidmuller

CIR BRKR MAG-HYDR 20A 240VAC

0

SU3C6UC

SU3C6UC

Weidmuller

CB PROTECTOR 1077 3P C 6A ACDC

13

9926283020

9926283020

Weidmuller

QL-AT-3(13)-DM-KM-20A

0

SU1D7UC

SU1D7UC

Weidmuller

CB PROTECTOR 1077 D 1P 7A

113

9124473500

9124473500

Weidmuller

CIR BRKR 16A 250VAC 80VDC

0

9926262501

9926262501

Weidmuller

CIR BRKR MAG-HYDR 1A 480VAC

0

SU2D15UC

SU2D15UC

Weidmuller

CB PROTECTOR 1077 2P D 15A ACDC

59

SU2C13UC

SU2C13UC

Weidmuller

CB PROTECTOR 1077 2P C 13A ACDC

50

9921101302

9921101302

Weidmuller

CB2211-10 W/O AUX T1 10A

0

67600653

67600653

Weidmuller

CIRCUIT BREAKER 8 AMP

0

9926252320

9926252320

Weidmuller

QZ-2-13-D-9-20

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top