Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9912031502

9912031502

Weidmuller

ETA 2210-T220-K0F2-HO-0.3A

0

9911600002

9911600002

Weidmuller

CB2211-10 W/O AUX 6A

0

9124263200

9124263200

Weidmuller

CIR BRKR 300MA 250VAC 80VDC

0

BR1D7UC

BR1D7UC

Weidmuller

CB MCB 489 1P D 7A ACDC

60

9911081105

9911081105

Weidmuller

CB2210-FAST NO AUX 0.8A

0

9912031302

9912031302

Weidmuller

CB2212-10 W/O AUX T1 0.3A

0

9926251206

9926251206

Weidmuller

QL-1-13-DM-1-06

0

SU2D20UC

SU2D20UC

Weidmuller

CB PROTECTOR 1077 2P D 20A ACDC

108

9104183200

9104183200

Weidmuller

CIR BRKR 200MA 250VAC 80VDC

0

9911801302

9911801302

Weidmuller

CB2211-10 W/O AUX T1 8A

0

BR1D35UC

BR1D35UC

Weidmuller

CB MCB 489 1P D 35A ACDC

8

BR3D50UC

BR3D50UC

Weidmuller

CB MCB 489 3P D 50A ACDC

40

6720005360

6720005360

Weidmuller

CIR BRKR THRM 500MA 24VDC

65

9926241105

9926241105

Weidmuller

QZ-1-13-D-3-05

0

9926283510

9926283510

Weidmuller

CIR BRKR MAG-HYDR 10A 480VAC

0

SU3D5UC

SU3D5UC

Weidmuller

CB PROTECTOR 1077 3P D 5A ACDC

26

SU3D60UC

SU3D60UC

Weidmuller

CB PROTECTOR 1077 3P D 60A ACDC

40

9926261906

9926261906

Weidmuller

QY-A-1-13-DM-U2-06

0

9926271525

9926271525

Weidmuller

CIR BRKR MAG-HYDR 25A 240VAC

0

9129623200

9129623200

Weidmuller

CIR BRKR 1.2A 250VAC 80VDC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top