Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9922250005

9922250005

Weidmuller

2210-T220-K0M1-H121-25A

0

9926241104

9926241104

Weidmuller

QZ-1-13-D-3-04

0

6720000047

6720000047

Weidmuller

ETA 8340 T120 K1K2 AEHO 3A

0

6720005392

6720005392

Weidmuller

CIR BRKR THRM 12A 24VDC SLD SWCH

49

9921121105

9921121105

Weidmuller

CB2211-10 W/NO AUX 12A F1 TRIP

0

9101903200

9101903200

Weidmuller

CIR BRKR 10A 250VAC 80VDC

0

9926251509

9926251509

Weidmuller

QZ-1-13-D-2-09

0

9926261905

9926261905

Weidmuller

QY-A-1-13-DM-U2-05

0

9922151302

9922151302

Weidmuller

CB2212-10 W/O AUX T1 15.0A

0

9124653500

9124653500

Weidmuller

CB4201-10 0.08A/TS35

0

9926283015

9926283015

Weidmuller

QL-AT-3(13)-DM-KM-15A

0

9913021302

9913021302

Weidmuller

CB2213-10 W/O AUX T1 0.2A

0

SU1D35UC

SU1D35UC

Weidmuller

CB PROTECTOR 1077 1P D 35A ACDC

167

9911500005

9911500005

Weidmuller

CIR BRKR THRMMAG 5A 480VAC 65VDC

5

9913200009

9913200009

Weidmuller

2210-T230-K0M1-H321 2A

0

SU2D30UC

SU2D30UC

Weidmuller

CB PROTECTOR 1077 2P D 30A ACDC

68

6720005370

6720005370

Weidmuller

CIR BRKR THRM 10A 24VDC SLD SWCH

91

9912200005

9912200005

Weidmuller

CB2212 2A NO CONTACT

0

SU3D10UC

SU3D10UC

Weidmuller

CB PROTECTOR 1077 3P D 10A ACDC

41

9926281020

9926281020

Weidmuller

CIR BRKR MAG-HYDR 20A 120VAC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure