Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9926261909

9926261909

Weidmuller

QY-A-1-13-DM-U2-09

0

SU2C4UC

SU2C4UC

Weidmuller

CB PROTECTOR 1077 2P C 4A ACDC

125

9921150005

9921150005

Weidmuller

CIR BRKR 15A 480VAC 65VDC

15

9974361902

9974361902

Weidmuller

CBH8341-10 25A

0

9926253025

9926253025

Weidmuller

QL-3(13)-DM-KM-25A

0

SU2D5UC

SU2D5UC

Weidmuller

CB PROTECTOR 1077 2P D 5A ACDC

0

9921251102

9921251102

Weidmuller

CB 2211-10 W/O AUXILIARY

0

SU1D13UC

SU1D13UC

Weidmuller

CB PROTECTOR 1077 1P D 13A ACDC

215

9926273515

9926273515

Weidmuller

CIR BRKR MAG-HYDR 15A 480VAC

0

9926252915

9926252915

Weidmuller

QY-2-13-DM-U2-15

162

9926271520

9926271520

Weidmuller

CIR BRKR MAG-HYDR 20A 240VAC

0

9101703200

9101703200

Weidmuller

CIR BRKR THRMMAG 3A 250VAC 80VDC

0

9124183500

9124183500

Weidmuller

CIR BRKR 11A 250VAC 80VDC

0

SU3C60UC

SU3C60UC

Weidmuller

CB PROTECTOR 1077 3P C 60A ACDC

16

9101503200

9101503200

Weidmuller

CIR BRKR THRMMAG 2A 250VAC 80VDC

0

9921160002

9921160002

Weidmuller

CB2212-1O W/O AUX 16A

0

9911801102

9911801102

Weidmuller

CB2211-10 W/O AUX 8A

0

9124423200

9124423200

Weidmuller

CIR BRKR THRMMAG 9A 250VAC 80VDC

0

9926282015

9926282015

Weidmuller

CIR BRKR MAG-HYDR 15A 240VAC

0

9921180005

9921180005

Weidmuller

CIR BRKR 18A 480VAC 65VDC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure