Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
BR3D12UC

BR3D12UC

Weidmuller

CB MCB 489 3P D 12A ACDC

85

9923151302

9923151302

Weidmuller

CB2210-10 TI W.O. AUX 15A

0

9912301100

9912301100

Weidmuller

CB2212-10 W/NO AUX 3.0A

0

9926241140

9926241140

Weidmuller

QZ-1-13-D-3-40

0

9926283520

9926283520

Weidmuller

CIR BRKR MAG-HYDR 20A 480VAC

0

9912102102

9912102102

Weidmuller

CB2212-10 W/O AUX T2 1.0A

0

67600702

67600702

Weidmuller

CIRCUIT BREAKER 10 AMP

0

9926252920

9926252920

Weidmuller

QY-2-13-DM-U2-20

174

SU2D8UC

SU2D8UC

Weidmuller

CB PROTECTOR 1077 2P D 8A ACDC

36

6720005368

6720005368

Weidmuller

CIR BRKR THRM 8A 24VDC SLD SWCH

66

9926253020

9926253020

Weidmuller

QL-3(13)-DM-KM-20A

0

9911151302

9911151302

Weidmuller

CB2211-10 W/O AUX T1 1.5A

0

9912051302

9912051302

Weidmuller

CB2212-10 W/O AUX T1 0.5A

0

9926282540

9926282540

Weidmuller

QZ-AT-2-13-D-2-40

0

9124443200

9124443200

Weidmuller

CIR BRKR 12A 250VAC 80VDC

0

9912081302

9912081302

Weidmuller

CB2212-10 W/O AUX T1 0.8A

0

SU2D7UC

SU2D7UC

Weidmuller

CB PROTECTOR 277/480V D 2P 7A

64

BR2D4UC

BR2D4UC

Weidmuller

CB MCB 489 2P D 4A ACDC

69

9926261900

9926261900

Weidmuller

QY-A-1-13-DM-U2-0.5

0

SU3D15UC

SU3D15UC

Weidmuller

CB PROTECTOR 1077 3P D 15A ACDC

99

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure