Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9913400003

9913400003

Weidmuller

CIR BRKR THRMMAG 4A 480VAC 65VDC

0

9926251516

9926251516

Weidmuller

QZ-1-13-D-2-16

0

9922321102

9922321102

Weidmuller

CB2210-20 F1 W/O AUX. 32A

0

9911151105

9911151105

Weidmuller

CB2211-10 W/NC AUX 1.5A

0

9912301205

9912301205

Weidmuller

2210-T220-K0M3-3A

0

9911601305

9911601305

Weidmuller

CB2211-10 TI NO AUX 6A

0

9921200002

9921200002

Weidmuller

CB2211-10 W/O AUX 20A

0

9926271005

9926271005

Weidmuller

CIR BRKR MAG-HYDR 5A 120VAC

0

9926252325

9926252325

Weidmuller

QZ-2-13-D-9-25

0

9129623500

9129623500

Weidmuller

CIR BRKR 1.2A 250VAC 80VDC

0

9926251507

9926251507

Weidmuller

QZ-1-13-D-2-07

0

SU1C8UC

SU1C8UC

Weidmuller

CB PROTECTOR 1077 1P C 8A ACDC

1137

9923160002

9923160002

Weidmuller

CB2213-10 W/OUT AUX M116A

0

9926261002

9926261002

Weidmuller

CIR BRKR MAG-HYDR 2A 120VAC

120

9921101100

9921101100

Weidmuller

2210-T210-KOF1-H131-10A

0

SU2D6UC

SU2D6UC

Weidmuller

CB PROTECTOR 1077 2P D 6A ACDC

3

9926251705

9926251705

Weidmuller

QY-1-13-DM-OP-05

0

6720005366

6720005366

Weidmuller

CIR BRKR THRM 6A 24VDC SLD SWCH

366

9129813200

9129813200

Weidmuller

CIR BRKR 300MA 250VAC 80VDC

0

9926281525

9926281525

Weidmuller

CIR BRKR MAG-HYDR 25A 240VAC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure