Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9926253015

9926253015

Weidmuller

QL-3(13)-DM-KM-15A

25

9913081302

9913081302

Weidmuller

CB2213-10 W/O AUX T1 0.8A

0

9974401902

9974401902

Weidmuller

CBH8342-10 15A W/O AUX

0

SU1D4UC

SU1D4UC

Weidmuller

CB PROTECTOR 1077 1P D 4A ACDC

110

9124373500

9124373500

Weidmuller

CIR BRKR THRMMAG 6A 250VAC 80VDC

1

9926253505

9926253505

Weidmuller

QZ-3-13-D-2-05

0

9926251306

9926251306

Weidmuller

QZ-1-13-D-9-06

0

SU1D40UC

SU1D40UC

Weidmuller

CB PROTECTOR 1077 1P D 40A ACDC

167

9921101502

9921101502

Weidmuller

CB2210-10 10A W/O AUX F2

0

9913100009

9913100009

Weidmuller

ETA 2210-T230-K0M1-H321 1A

0

9926273020

9926273020

Weidmuller

QL-T-3(13)-DM-KM-20A

0

9926273525

9926273525

Weidmuller

CIR BRKR MAG-HYDR 25A 480VAC

0

9926251405

9926251405

Weidmuller

QY-1-13-DM-1-05

0

9911601102

9911601102

Weidmuller

CB2211-10 F1 W/O AUX.CONTACT

0

9120043500

9120043500

Weidmuller

CIR BRKR 6.5A 250VAC 80VDC

0

9926271010

9926271010

Weidmuller

CIR BRKR MAG-HYDR 10A 120VAC

0

9926272501

9926272501

Weidmuller

CIR BRKR MAG-HYDR 1A 480VAC

0

9926251909

9926251909

Weidmuller

QY-1-13-DM-2-09

0

9103003200

9103003200

Weidmuller

CIR BRKR THRMMAG 8A 250VAC 80VDC

0

9926243010

9926243010

Weidmuller

QZ-3-13-D-1-10

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top