Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9922101309

9922101309

Weidmuller

CB2212-10 W/NO AUX 1 POLE 10A

0

9923321302

9923321302

Weidmuller

CB2213-10 W/O AUX T1 32.0A

0

9124463200

9124463200

Weidmuller

CIR BRKR 14A 250VAC 80VDC

0

9912300005

9912300005

Weidmuller

CB2212-10 W/NO AUX 3A

0

9926251803

9926251803

Weidmuller

CIR BRKR MAG-HYDR 3A 125VDC

12

BR3C4UC

BR3C4UC

Weidmuller

CB MCB 489 3P C 4A ACDC

40

9921250005

9921250005

Weidmuller

CIR BRKR 25A 480VAC 65VDC

0

9926282001

9926282001

Weidmuller

CIR BRKR MAG-HYDR 1A 240VAC

0

9926271020

9926271020

Weidmuller

CIR BRKR MAG-HYDR 20A 120VAC

0

9922161309

9922161309

Weidmuller

CB2212-10 W/NO AUX 1 POLE 1

0

SU2C60UC

SU2C60UC

Weidmuller

CB PROTECTOR 1077 2P C 60A ACDC

30

9926252099

9926252099

Weidmuller

QL-2-13-DM-KM-0.1

0

9923151303

9923151303

Weidmuller

CB 2210-T230-KOT1-H3A1- 15 AMP

0

6720005384

6720005384

Weidmuller

CIR BRKR THRM 4A 24VDC SLD SWCH

0

9129613500

9129613500

Weidmuller

CIR BRKR THRMMAG 1A 250VAC 80VDC

5

9911301302

9911301302

Weidmuller

CB2210-T210-KOT1-HO-3A

0

9120353200

9120353200

Weidmuller

CIR BRKR 100MA 250VAC 80VDC

0

6720005317

6720005317

Weidmuller

JUMPERS FOR ESX10-T

0

9911031302

9911031302

Weidmuller

CB2211-10 W/O AUX T1 0.3A

0

9926251205

9926251205

Weidmuller

QL-1-13-DM-1-05

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure