Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9926272525

9926272525

Weidmuller

CIR BRKR MAG-HYDR 25A 480VAC

0

9926251804

9926251804

Weidmuller

CIR BRKR MAG-HYDR 4A 125VDC

240

9911030005

9911030005

Weidmuller

CIR BRKR 300MA 480VAC 65VDC

0

9926252202

9926252202

Weidmuller

QL-2-13-DM-1-02

24

SU3C13UC

SU3C13UC

Weidmuller

CB PROTECTOR 1077 3P C 13A ACDC

18

9926291160

9926291160

Weidmuller

QF17A2560 - CB W/GFI

0

9107843500

9107843500

Weidmuller

CIR BRKR 12A 250VAC 80VDC

60

9911601302

9911601302

Weidmuller

CB2210-10 T1 NO AUX 6A

0

9124113200

9124113200

Weidmuller

CIR BRKR 600MA 250VAC 80VDC

0

9124383500

9124383500

Weidmuller

CIR BRKR 6.5A 250VAC 80VDC

0

9124343500

9124343500

Weidmuller

CIR BRKR 3.5A 250VAC 80VDC

0

SU2C8UC

SU2C8UC

Weidmuller

CB PROTECTOR 1077 2P C 8A ACDC

47

9923180003

9923180003

Weidmuller

CIR BRKR 18A 480VAC 65VDC

0

9926261001

9926261001

Weidmuller

CIR BRKR MAG-HYDR 1A 120VAC

0

9129633200

9129633200

Weidmuller

CIR BRKR 1.5A 250VAC 80VDC

0

BR3C40UC

BR3C40UC

Weidmuller

CB MCB 489 3P C 40A ACDC

61

9926252203

9926252203

Weidmuller

QL-2-13-DM-1-03

0

BR3D6UC

BR3D6UC

Weidmuller

CB MCB 489 3P D 6A ACDC

45

9926263525

9926263525

Weidmuller

CIR BRKR MAG-HYDR 25A 480VAC

0

9926251808

9926251808

Weidmuller

QY-1-13-DM-U2-08-B1 125 VDC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure