Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
9912030003

9912030003

Weidmuller

CIR BRKR 300MA 480VAC 65VDC

0

9912600003

9912600003

Weidmuller

CIR BRKR THRMMAG 6A 480VAC 65VDC

0

9124283500

9124283500

Weidmuller

CIR BRKR 600MA 250VAC 80VDC

0

9921181302

9921181302

Weidmuller

CB2211-10 W/O AUX T1 18.0A

0

9970630000

9970630000

Weidmuller

CQB 10 ANGLES COMB 2/IP

0

9926283515

9926283515

Weidmuller

CIR BRKR MAG-HYDR 15A 480VAC

0

BR3C32UC

BR3C32UC

Weidmuller

CB MCB 489 3P C 32A ACDC

106

BR1C60UC

BR1C60UC

Weidmuller

CB MCB 489 1P C 60A ACDC

107

9926281502

9926281502

Weidmuller

CIR BRKR MAG-HYDR 2A 240VAC

0

9911251302

9911251302

Weidmuller

CB2211-10 W/O AUX T1 2.5A

0

9926281001

9926281001

Weidmuller

CIR BRKR MAG-HYDR 1A 120VAC

0

9926261005

9926261005

Weidmuller

CIR BRKR MAG-HYDR 5A 120VAC

0

9912401302

9912401302

Weidmuller

CB2212-10 W/O AUX 4.0A

0

9124433500

9124433500

Weidmuller

CIR BRKR 11A 250VAC 80VDC

0

6720005390

6720005390

Weidmuller

CIR BRKR THRM 10A 24VDC SLD SWCH

35

9911150005

9911150005

Weidmuller

CIR BRKR 1.5A 480VAC 65VDC

0

9913600003

9913600003

Weidmuller

CIR BRKR THRMMAG 6A 480VAC 65VDC

0

BR2D13UC

BR2D13UC

Weidmuller

CB MCB 489 2P D 13A ACDC

27

9921181105

9921181105

Weidmuller

CB2211 -10 W/NO AUX.18A FAST

0

9926251204

9926251204

Weidmuller

QL-1-13-DM-1-04

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure