Accessories

Image Part Number Description / PDF Quantity Rfq
PIDT600-2

PIDT600-2

Fluke Electronics

DIRT & MOISTURE TRAP 1/8 NPT 20

0

PR1230

PR1230

Fluke Electronics

ACCESSORY

0

PR1000/ST

PR1000/ST

Fluke Electronics

ACCESSORY

0

FLK-XLENS/MACRO1

FLK-XLENS/MACRO1

Fluke Electronics

INFRARED CLOSE-UP LENS

0

IP-200-US

IP-200-US

Fluke Electronics

2" & 3" US WINDOW"STALLATION KIT

0

4524-C-60

4524-C-60

Fluke Electronics

CABLE TEST BNC

0

PR01ACV

PR01ACV

Fluke Electronics

ACCESSORY KIT

0

PR1201 ACI

PR1201 ACI

Fluke Electronics

ACCESSORY 2551557

0

C570

C570

Fluke Electronics

CASE 57X SERIES SOFT

0

FLK-XLENS CAL

FLK-XLENS CAL

Fluke Electronics

INFRARED LENS CALIBRATION

0

PR3001MACV

PR3001MACV

Fluke Electronics

ACCESSORY

0

PR1002MACI

PR1002MACI

Fluke Electronics

ACCESSORY

0

LIC-9938

LIC-9938

Fluke Electronics

LIC MET/TEMP II TO MET/TRACK 7.0

0

2633-USB

2633-USB

Fluke Electronics

RECEIVER USB TO WIRELESS (1620A)

0

FLK-XLENS/TELE

FLK-XLENS/TELE

Fluke Electronics

INFRARED TELEPHOTO LENS

0

FLK-075-CLV

FLK-075-CLV

Fluke Electronics

3" INDOOR LOW VOLT KWIK TWIST

0

WC17XX

WC17XX

Fluke Electronics

17XX COLOR CODE WIRE CLIPS LARGE

0

PR221 ACV

PR221 ACV

Fluke Electronics

ACCESSORY

0

PR1800/SP1

PR1800/SP1

Fluke Electronics

ACCESSORY

0

PR3002MACI

PR3002MACI

Fluke Electronics

ACCESSORY

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top