Accessories

Image Part Number Description / PDF Quantity Rfq
FLK-LENS/TELE1

FLK-LENS/TELE1

Fluke Electronics

INFRARED TELEPHOTO LENS 1

0

FLK-XHDMI CABLE

FLK-XHDMI CABLE

Fluke Electronics

CBL HDMI LEMO CONN

0

SPSCAN6000

SPSCAN6000

Fluke Electronics

SCANNER FLUKE-6200-2/6500-2 PORT

0

PR2000 CH

PR2000 CH

Fluke Electronics

ACCESSORY

0

FLUKE-CV201

FLUKE-CV201

Fluke Electronics

2" IR WINDOW KEY DOOR LATCH

0

BE9005 120

BE9005 120

Fluke Electronics

BATTERY PACK NIMH

0

FVF-SC1

FVF-SC1

Fluke Electronics

FLUKEVIEW FORMS W/CABLE

0

FLK-TI-SBC

FLK-TI-SBC

Fluke Electronics

IR SMART BATTERY CHARGER

0

87-RETROFIT

87-RETROFIT

Fluke Electronics

KIT RETROFIT FOR 80 SERIES METER

0

FLK-075-CLKTO

FLK-075-CLKTO

Fluke Electronics

3" C-RANGE MED VOLT KWIK TWIST

0

FLK-XCHARGER

FLK-XCHARGER

Fluke Electronics

CHARGER BATTERY SONY

0

FLK-XSUBWINDOW

FLK-XSUBWINDOW

Fluke Electronics

CALIBRATION FOR SUB WINDOW

0

PR3000MACV

PR3000MACV

Fluke Electronics

ACCESSORY

0

SV225/10PAK

SV225/10PAK

Fluke Electronics

ADAPTER STRAY VOLTAGE 10 PACK

0

BP189

BP189

Fluke Electronics

BATTER PACK FOR FLUKE 180 SERIES

0

FLK-XLENS/WIDE

FLK-XLENS/WIDE

Fluke Electronics

INFRARED WIDE ANGLE

0

9939-CM

9939-CM

Fluke Electronics

SOFTWARE MET/TEMP-CM

0

2633-232

2633-232

Fluke Electronics

RECEIVER RS232 TO WIRELESS (1620

0

2457439

2457439

Fluke Electronics

MTC515 TEST CORD NEMA

0

VT-BATT-CHG

VT-BATT-CHG

Fluke Electronics

90-264VAC TO CHRG 4 AA NI-MH CEL

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top