Accessories

Image Part Number Description / PDF Quantity Rfq
FLK-XCALIBRATION

FLK-XCALIBRATION

Fluke Electronics

CALIBRATION ADJUSTMENT

0

A81115

A81115

Fluke Electronics

BATTERY CHARGER/ELIMINATOR

0

PR25ACV

PR25ACV

Fluke Electronics

ACCESSORY

0

PR1002ACI

PR1002ACI

Fluke Electronics

ACCESSORY

0

FLK-XLENS/SUPTELE

FLK-XLENS/SUPTELE

Fluke Electronics

INFRARED TELEPHOTO LENS

0

FLK-XETHERNET 5M

FLK-XETHERNET 5M

Fluke Electronics

CBL ETHERNET LEMO CONN 5M

0

PM8907/813

PM8907/813

Fluke Electronics

POWER ADAPTER/BATTERY CHARGER US

0

PR3001ACV

PR3001ACV

Fluke Electronics

ACCESSORY

0

PR205ACV

PR205ACV

Fluke Electronics

ACCESSORY

0

PR1500/SP12

PR1500/SP12

Fluke Electronics

ACCESSORY

0

PR1001ACV/SP2

PR1001ACV/SP2

Fluke Electronics

ACCESSORY

0

PR3000MACI

PR3000MACI

Fluke Electronics

ACCESSORY

0

PR600MACI

PR600MACI

Fluke Electronics

ACCESSORY

0

PR3000ACV

PR3000ACV

Fluke Electronics

ACCESSORY

0

PIDT600-8

PIDT600-8

Fluke Electronics

TRAP 1/4 BSP 210 BAR/3000 PSI

0

PR400MACI

PR400MACI

Fluke Electronics

ACCESSORY

0

PR1201 ACV

PR1201 ACV

Fluke Electronics

ACCESSORY

0

5315-005

5315-005

Fluke Electronics

SPARE BATTERY IS-APPROVED

0

FLUKE-1750/MC2GB

FLUKE-1750/MC2GB

Fluke Electronics

1750 2GB SECURE DIG MEM CARD

0

M00-200-634

M00-200-634

Fluke Electronics

KIT RACKMOUNT

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top