Accessories

Image Part Number Description / PDF Quantity Rfq
Y8022

Y8022

Fluke Electronics

CABLE SHIELDED IEEE488 2M

0

PR1007MACV

PR1007MACV

Fluke Electronics

ACCESSORY

0

PR30ACV

PR30ACV

Fluke Electronics

ACCESSORY

0

C1730

C1730

Fluke Electronics

FLUKE-1730 SOFT CASE

0

600CKA

600CKA

Fluke Electronics

VOLTAGE TRANSFORMER FOR CT-326B

0

PR3001ACI

PR3001ACI

Fluke Electronics

ACCESSORY

0

TPAK/NAP

TPAK/NAP

Fluke Electronics

ACCESSORY TEST PROBE

0

3100SK-V

3100SK-V

Fluke Electronics

SEAL KIT - 31XX & 32XX MODELS -

0

FLK-CNX C3302

FLK-CNX C3302

Fluke Electronics

FLK-C3003, 3-COMPARTMENT SOFT

0

Y8021

Y8021

Fluke Electronics

CABLE SHIELDED IEEE488 1M

0

FLK-XLENS/MACRO3

FLK-XLENS/MACRO3

Fluke Electronics

INFRARED CLOSE-UP LENS

0

PR3003MACI

PR3003MACI

Fluke Electronics

ACCESSORY

0

PR100/SP58

PR100/SP58

Fluke Electronics

ACCESSORY

0

PR1200MACV

PR1200MACV

Fluke Electronics

ACCESSORY 2551867

0

GEOX CABLESET

GEOX CABLESET

Fluke Electronics

ADPTR CBL SET GEOX FOR STAKELESS

0

SP6000 PRINTER

SP6000 PRINTER

Fluke Electronics

FLUKE-6200-2/6500-2 PORTABLE APP

0

PR102ACI

PR102ACI

Fluke Electronics

ACCESSORY

0

104543

104543

Fluke Electronics

VEHICLE ADAPTER BATTERY CHARGER

0

FLK 0.75X WIDE LENS

FLK 0.75X WIDE LENS

Fluke Electronics

INFRARED WIDE ANGLE LENS

0

FLK-VT04-HARD CASE

FLK-VT04-HARD CASE

Fluke Electronics

VT HARD CASE

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top