Accessories

Image Part Number Description / PDF Quantity Rfq
05S106-S20S3

05S106-S20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

60S36R-MSON3

60S36R-MSON3

Rosenberger

7/16 CALIBRATION KIT

0

64S12L-000S3

64S12L-000S3

Rosenberger

4.3/10 OPEN

0

08K12L-000S3

08K12L-000S3

Rosenberger

PRECISION 1.85 OPEN

0

19K150-C10D3

19K150-C10D3

Rosenberger

SMP CALIBRATION LOAD

0

02S12S-001D3

02S12S-001D3

Rosenberger

PRECISION 2.92 SHORT

0

09S12L-000S3

09S12L-000S3

Rosenberger

PRECISION 2.40 OPEN

0

18S12S-000D3

18S12S-000D3

Rosenberger

MINI SMP SHORT

0

03S30R-MSOS3

03S30R-MSOS3

Rosenberger

PRECISION 3.5 CALIBRATION KIT

0

119S150-C10D3

119S150-C10D3

Rosenberger

PSMP CALIBRATION LOAD

0

01K101-K20D3

01K101-K20D3

Rosenberger

PRECISION 1.00 CALIBRATION ADAPT

0

19S121-S20D3

19S121-S20D3

Rosenberger

SMP CALIBRATION ADAPTER

0

119S12L-000D3

119S12L-000D3

Rosenberger

PSMP OPEN

0

02S12L-000S3

02S12L-000S3

Rosenberger

PRECISION 2.92 OPEN

0

60S121-S20S3

60S121-S20S3

Rosenberger

7/16 CALIBRATION ADAPTER

0

02K119-K20D3

02K119-K20D3

Rosenberger

PRECISION 2.92 CALIBRATION ADAPT

0

06K121-K20S3

06K121-K20S3

Rosenberger

PRECISION TNC CALIBRATION ADAPTO

0

09K121-K20S3

09K121-K20S3

Rosenberger

PRECISION 2.40 CALIBRATION ADAPT

0

08K12S-000S3

08K12S-000S3

Rosenberger

PRECISION 1.85 SHORT

0

60S12S-000S3

60S12S-000S3

Rosenberger

7/16 SHORT

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top