Accessories

Image Part Number Description / PDF Quantity Rfq
71S12L-000S3

71S12L-000S3

Rosenberger

BNC 75 OHM OPEN

0

119K101-K20D3

119K101-K20D3

Rosenberger

PSMP CALIBRATION ADAPTER

0

03K1AM-S20S3

03K1AM-S20S3

Rosenberger

PRECISION 3.50 CALIBRATION ADAPT

0

05K121-K20S3

05K121-K20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

53K38R-MSON3

53K38R-MSON3

Rosenberger

N TYPE CALIBRATION KIT

0

P5S12L-00AS3

P5S12L-00AS3

Rosenberger

N TYPE OPEN

0

05K151-K20S3

05K151-K20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

03S121-S20S3

03S121-S20S3

Rosenberger

PRECISION 3.5 CALIBRATION ADAPTO

0

02S121-K20S3

02S121-K20S3

Rosenberger

PRECISION 2.92 CALIBRATION ADAPT

0

18K12S-000D3

18K12S-000D3

Rosenberger

MINI SMP SHORT

0

03K110-K21S3

03K110-K21S3

Rosenberger

PRECISION 3.5 CALIBRATION ADAPTO

0

51K12L-000S3

51K12L-000S3

Rosenberger

BNC OPEN

0

03S128-S20N3

03S128-S20N3

Rosenberger

PRECISION 3.5 CALIBRATION ADAPTO

0

19S12S-000D3

19S12S-000D3

Rosenberger

SMP SHORT

0

51S12L-000S3

51S12L-000S3

Rosenberger

BNC OPEN

0

03S159-S20S3

03S159-S20S3

Rosenberger

PRECISION 3.5 CALIBRATION ADAPTO

0

03K128-S20N3

03K128-S20N3

Rosenberger

PRECISION 3.5 CALIBRATION ADAPTO

0

18K150-C10D3

18K150-C10D3

Rosenberger

MINI SMP CALIBRATION LOAD

0

119K150-C10D3

119K150-C10D3

Rosenberger

PSMP CALIBRATION LOAD

0

06S12S-000S3

06S12S-000S3

Rosenberger

PRECISION TNC SHORT

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top