Accessories

Image Part Number Description / PDF Quantity Rfq
119S12S-000D3

119S12S-000D3

Rosenberger

PSMP SHORT

0

05S12S-000S3

05S12S-000S3

Rosenberger

PRECISION N TYPE SHORT

0

60K36R-MSON3

60K36R-MSON3

Rosenberger

7/16 CALIBRATION KIT

0

AMCK010-150

AMCK010-150

Rosenberger

HFM CALIBRATION KIT

0

05S160-S20S3

05S160-S20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

03S110-K21S3

03S110-K21S3

Rosenberger

PRECISION 3.5 CALIBRATION ADAPTO

0

18S12L-000D3

18S12L-000D3

Rosenberger

MINI SMP OPEN

0

03S1AM-K20S3

03S1AM-K20S3

Rosenberger

PRECISION 3.50 CALIBRATION ADAPT

0

51K170-C10S3

51K170-C10S3

Rosenberger

BNC CALIBRATION LOAD

0

P5K30R-MSOTS3

P5K30R-MSOTS3

Rosenberger

N TYPE CALIBRATION KIT

0

09K150-C10S3

09K150-C10S3

Rosenberger

PRECISION 2.40 CALIBRATION LOAD

0

09S121-K20S3

09S121-K20S3

Rosenberger

PRECISION 2.40 CALIBRATION ADAPT

0

03S1AM-S20S3

03S1AM-S20S3

Rosenberger

PRECISION 3.50 CALIBRATION ADAPT

0

03K30R-MSOS3

03K30R-MSOS3

Rosenberger

PRECISION 3.5 CALIBRATION KIT

0

P5S12S-00AS3

P5S12S-00AS3

Rosenberger

N TYPE SHORT

0

05K164-K20S3

05K164-K20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

64K150-C10S3

64K150-C10S3

Rosenberger

4.3/10 CALIBRATION LOAD

0

05S151-S20S3

05S151-S20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

65S36R-MSOS3

65S36R-MSOS3

Rosenberger

4.1/9.5 CALIBRATION KIT

0

02K30R-MSOS3

02K30R-MSOS3

Rosenberger

PRECISION 2.92 CALIBRATION KIT

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email