Accessories

Image Part Number Description / PDF Quantity Rfq
05K165-K20S3

05K165-K20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

06S150-C10S3

06S150-C10S3

Rosenberger

PRECISION TNC CALIBRATION LOAD

0

09K12S-000S3

09K12S-000S3

Rosenberger

PRECISION 2.40 SHORT

0

05S30R-MSOS3

05S30R-MSOS3

Rosenberger

PRECISION N TYPE CALIBRATION KIT

0

19K12L-000D3

19K12L-000D3

Rosenberger

SMP OPEN

0

08K150-C10S3

08K150-C10S3

Rosenberger

PRECISION 1.85 CALIBRATION LOAD

0

08S121-S20S3

08S121-S20S3

Rosenberger

PRECISION 1.85 CALIBRATION ADAPT

0

64S12S-000S3

64S12S-000S3

Rosenberger

4.3/10 SHORT

0

18CK010-150

18CK010-150

Rosenberger

MINI SMP CALIBRATION KIT

0

05S121-S20S3

05S121-S20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

06K12S-000S3

06K12S-000S3

Rosenberger

PRECISION TNC SHORT

0

60K34R-MSON3

60K34R-MSON3

Rosenberger

7/16 CALIBRATION KIT

0

153QK105-K20S3

153QK105-K20S3

Rosenberger

QN CALIBRATION ADAPTER

0

03K12S-001D3

03K12S-001D3

Rosenberger

PRECISION 3.5 SHORT

0

53S36R-MSON3

53S36R-MSON3

Rosenberger

N TYPE CALIBRATION KIT

0

71K170-C10S3

71K170-C10S3

Rosenberger

BNC 75 OHM CALIBRATION LOAD

0

19K121-K20D3

19K121-K20D3

Rosenberger

SMP CALIBRATION ADAPTER

0

05S160-S50D3

05S160-S50D3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

64S121-K20S3

64S121-K20S3

Rosenberger

4.3/10 CALIBRATION ADAPTER

0

05K160-K50D3

05K160-K50D3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email