Accessories

Image Part Number Description / PDF Quantity Rfq
M1011

M1011

Comet America

D2 INPUT 0-10V

20

CTM-29-0

CTM-29-0

Cal Test Electronics

GENERAL PURPOSE/GEOPHONE INSULAT

40

CTM-62-0

CTM-62-0

Cal Test Electronics

ALLIGATOR INSULATOR VINYL BLACK

0

4112738

4112738

Fluke Electronics

GOLDCAREPLAN-GROUP2-3YR

0

REFL-SSA3000X

REFL-SSA3000X

Siglent Technologies

VSWR/RETURN LOSS ACTIVATION LICE

4

08S150-C10S3

08S150-C10S3

Rosenberger

PRECISION 1.85 CALIBRATION LOAD

0

ASTM 4 - 1000G

ASTM 4 - 1000G

Adam Equipment

ASTM WEIGHTS

50

CT3197B

CT3197B

Cal Test Electronics

IMPEDANCE CONVERTER SET IMPROVED

5

DX10-QC

DX10-QC

Teledyne LeCroy

REPLACEMENT QC LEAD SET DX10

0

119S12S-000D3

119S12S-000D3

Rosenberger

PSMP SHORT

0

AI-000480

AI-000480

Mueller Electric Co.

CABLE ASSY GND BU-122 1M

4820

BU-26-0

BU-26-0

Mueller Electric Co.

INSULATOR FOR BU-24,25 SRS BLACK

9552000

4112678

4112678

Fluke Electronics

GOLDCAREPLAN-GROUP1-3YR

0

82-2GRY

82-2GRY

E-Z-Hook

CLAMP WIRE INSUL PIERC GRAY

0

ASTM 2 - 1000G

ASTM 2 - 1000G

Adam Equipment

ASTM WEIGHTS

10

VDV999-065

VDV999-065

Klein Tools

PROBEPLUS TIP

1

777101-01

777101-01

NI

CB-50LP CONNECTOR BLOCK W/O CABL

3

ASTM 4 - 500G

ASTM 4 - 500G

Adam Equipment

ASTM WEIGHTS

50

05S12S-000S3

05S12S-000S3

Rosenberger

PRECISION N TYPE SHORT

0

BU-31-5

BU-31-5

Mueller Electric Co.

INSULATOR

3321

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top