Accessories

Image Part Number Description / PDF Quantity Rfq
PWQ08V50

PWQ08V50

Bartovation

NITRITE 0-25 PPM, NITRATE 0-500

100

RS500

RS500

Fluke Electronics

PROBE REPLACEMENT SET

0

R5600-CLIP

R5600-CLIP

REED Instruments

REPLACEMENT ALLIGATOR CLIP

2

MP027

MP027

Comet America

SIDE COVERS FOR CABLES

20

Y4028100K000V0I

Y4028100K000V0I

VPG Foil

RES 100K OHM .2W .005% FOIL

2

TET-6

TET-6

OK Industries (Jonard Tools)

ACCESSORY KIT FOR TET-700

0

R5900

R5900

REED Instruments

MAGNETIC HANGING STRAP

14

CRC01M

CRC01M

Peak Electronic Design Ltd

GOLD PLATED RED/BLACK CROCS FOR

60

SVA1000X-AMA

SVA1000X-AMA

Siglent Technologies

ANALOG MODULATION ANALYSIS (AM/F

4

VS-CKBB6-2

VS-CKBB6-2

Panduit Corporation

VERISAFE CONNECTION KIT FOR TAPP

5

60K36R-MSON3

60K36R-MSON3

Rosenberger

7/16 CALIBRATION KIT

0

GAM-100

GAM-100

ICP DAS USA Inc.

BLUETOOTH LE GAUGE MASTER

30

AMCK010-150

AMCK010-150

Rosenberger

HFM CALIBRATION KIT

0

MLP007

MLP007

Comet America

WATERTIGHT CASE FOR MULTILOGGER

20

PSS04V50

PSS04V50

Bartovation

SALINITY SALT TEST STRIPS, 0-100

100

IRW-4C

IRW-4C

FLIR

FLIR IRW INFRARED WINDOW 4" (O.D

1

EL-CC-BAG

EL-CC-BAG

Lascar Electronics

PACK OF 5 WATERPROOF BAGS

10

72-127-4

72-127-4

NTE Electronics, Inc.

YELLOW INSULATOR FOR 72-124/126

772

BU-47-4

BU-47-4

Mueller Electric Co.

INSULATOR

3191181

1405-XR

1405-XR

3M

EMS 4" EXTENDED RANGE 5' BALL MA

24

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments