Accessories

Image Part Number Description / PDF Quantity Rfq
AK57X

AK57X

B&K Precision

INTERFACE SOFTWARE W/USB DONGLE

0

C173X

C173X

Fluke Electronics

SOFT CASE FLUKE-173X

0

AC1000A UK

AC1000A UK

AIMtti

POWER SUPP LOW DISTORTION 1KW

0

PACC-LD005

PACC-LD005

Teledyne LeCroy

GROUND LEAD (QTY 4)

6

KATESTLEAD10

KATESTLEAD10

SRA Soldering Products

POWER SUPPLY TEST LEAD SET 10 AM

61

PK003

PK003

Teledyne LeCroy

PRB ACCESS PP061/62/64

1

Y4028150R000V0I

Y4028150R000V0I

VPG Foil

RES 150 OHM .2W .005% FOIL

0

R1007

R1007

REED Instruments

7PH BUFFER POUCHES, 20-PACK

5

785024-01

785024-01

NI

SCB-100A NOISE REJECTING, SHIELD

9

M1004

M1004

Comet America

B1 INPUT MOD,MS LOGGER 0-1A

20

Y4028313R332V0I

Y4028313R332V0I

VPG Foil

RES 313.332 OHM .2W .005% FOIL

0

05S160-S20S3

05S160-S20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

CTM-8681-0

CTM-8681-0

Cal Test Electronics

INSULATOR FOR TELCOM CLIPS BLACK

498

1408-XR

1408-XR

3M

EMS 4" EXTENDED RANGE 5' BALL MA

0

BU-31-2

BU-31-2

Mueller Electric Co.

INSULATOR FOR BU-30BL,30TBO RED

12627000

TC-K-01-CA003

TC-K-01-CA003

Cicoil

THERMOCOUPLE K 28AWG 3'

57

ASTM 2 -10G

ASTM 2 -10G

Adam Equipment

ASTM WEIGHTS

50

2609

2609

Fluke Electronics

CASE LONG PROBE CARRYING

0

110990101

110990101

Seeed

RF EXPLORER HOLDER

0

MD046

MD046

Comet America

VESSEL FOR CALIBRATION RH

20

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top