Accessories

Image Part Number Description / PDF Quantity Rfq
PK007-011

PK007-011

Teledyne LeCroy

IC-CAP FOR 1. MM PACK 10

1

HDO4K-USB2BUS TD

HDO4K-USB2BUS TD

Teledyne LeCroy

USB 2.0 BUS DECODE OPTION

0

10-4295

10-4295

Triplett Test Equipment and Tools

UNIVERSAL CARRYING CASE

10

P5S170-C1AS3

P5S170-C1AS3

Rosenberger

N TYPE CALIBRATION LOAD

0

M1060

M1060

Comet America

K3 MOD.FOR MS RTD SENSOR PT1000

20

MP048

MP048

Comet America

MS6D DATALOGGER IP54 CASE

20

PK007-029

PK007-029

Teledyne LeCroy

GROUND LEAD WITH 4 MM PLUG

12

72-166-6

72-166-6

NTE Electronics, Inc.

BLUE INSULATOR FOR 72-167/168

780

A402

A402

TPI (Test Products International)

SOFTWARE FOR TPI 440

33

M1025

M1025

Comet America

A1G INPUT MOD,MS LOGGER 4-20MA

20

AI-000151-20

AI-000151-20

Mueller Electric Co.

CABLE GROUND CLIPS SS 10AWG 20FT

18

M1037

M1037

Comet America

NG INPUT MODULE FOR LOGGER MS

20

EI-1625

EI-1625

Fluke Electronics

CLAMP SET SELECTIVE/STAKELESS

0

03K121-K20S3

03K121-K20S3

Rosenberger

PRECISION 3.5 CALIBRATION ADAPTO

0

BU-26-9

BU-26-9

Mueller Electric Co.

INSULATOR AUTO PVC WHITE 3.88"

134

16153

16153

Palmer Wahl Instruments, Inc.

R10 TWO AXIS MOUNTING BRACKET

5

PK007-013

PK007-013

Teledyne LeCroy

GND BLADE PK OF 5

4

TMPCNM05

TMPCNM05

Red Lion

QUICK DISCONNECT MINI CONNECTOR

8

CT2712A-8

CT2712A-8

Cal Test Electronics

TIP INSULATOR GRAY 5MM

238

MP050

MP050

Comet America

OUTPUT RELAYS MODULE

20

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email