Accessories

Image Part Number Description / PDF Quantity Rfq
119K12S-000D3

119K12S-000D3

Rosenberger

PSMP SHORT

0

PACC-LD004

PACC-LD004

Teledyne LeCroy

RIGHT ANGLE LEAD LONG 4/PC

1

IRW-24PS

IRW-24PS

FLIR

LARGE FORMAT IR INSPECTION WINDO

2

AI-000474-120

AI-000474-120

Mueller Electric Co.

GROUND CABLE THHN TO BU-25C

6

C10

C10

Fluke Electronics

HOLSTER METER

0

PK033

PK033

Teledyne LeCroy

AP033/AP034 ACCES KIT

3

ES05

ES05

Mark-10

TEST STAND, LEVER-OPERATED, 30 L

10

PCL06V100

PCL06V100

Bartovation

ACTIVE CHLORINE/BLEACH TEST STRI

100

SDS-5000X-FG

SDS-5000X-FG

Siglent Technologies

WAVEFORM GENERATOR ACTIVATION LI

4

LIVESCAN ANTENNA KIT

LIVESCAN ANTENNA KIT

Siretta

DIRECTIONAL ANTENNA FOR SNYPER S

4

CTM-23-5

CTM-23-5

Cal Test Electronics

MED HEAVY DUTY CLIP INSULATOR VI

230

72-127-2

72-127-2

NTE Electronics, Inc.

RED INSULATOR FOR 72-124/126

293

VS-ACK-BATTERY

VS-ACK-BATTERY

Panduit Corporation

BATTERY PACK FOR USE WITH VERISA

936

VDV726-125

VDV726-125

Klein Tools

JUMPER CABLE FOR TEST-N-MAP REMO

3

192061-01

192061-01

NI

SHC68-68-EPM SHIELDED CABLE, 68-

25

09S12S-000S3

09S12S-000S3

Rosenberger

PRECISION 2.40 SHORT

0

A100

A100

TPI (Test Products International)

SOFT CARRYING CASE

100

18903

18903

Aven

REPLACEMENT TIP BENT

2

72-157-6

72-157-6

NTE Electronics, Inc.

BLUE INSULATOR FOR 72-148/149/15

1370

R9800

R9800

REED Instruments

DIGITAL SCALE

207

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top