Accessories

Image Part Number Description / PDF Quantity Rfq
BAG-S2

BAG-S2

Siglent Technologies

SOFT CARRY CASE - LARGE (18 X 1

5

PK007-014

PK007-014

Teledyne LeCroy

COPPER PAD PACK OF 25

9

A614

A614

TPI (Test Products International)

PROTECTIVE BOOT WITH MAGNETS

175

72-122-4

72-122-4

NTE Electronics, Inc.

YEL INSULATOR FOR 72-120/121

101

AI-000454-6

AI-000454-6

Mueller Electric Co.

CABLE ASMY AUTO CLIP 100A LGTH

12

72-127-0

72-127-0

NTE Electronics, Inc.

BLACK INSULATOR FOR 72-124/126

1521

A712

A712

TPI (Test Products International)

SENSOR WITH CAP

38

SCC120B

SCC120B

Fluke Electronics

SCC120B, SOFTWARE SOFT CARRY CAS

0

BU-43PR-0

BU-43PR-0

Mueller Electric Co.

INSULATOR FOR BU-41 BLACK 1 PAIR

71

SSA3000XP-DMA

SSA3000XP-DMA

Siglent Technologies

DIGITAL MODULATION ANALYSIS (ASK

4

BU-26-2

BU-26-2

Mueller Electric Co.

INSULATOR FOR BU-24,25 SRS RED

255310000

72-176-9

72-176-9

NTE Electronics, Inc.

WHT INSULATOR FOR 72-173/173PS/1

797

S19-501

S19-501

Harwin

SPRING PROBE SLEEVE

2958

BU-43PR-2

BU-43PR-2

Mueller Electric Co.

INSULATOR FOR BU-41 RED 1 PAIR

184

399-0181-S

399-0181-S

Staco Energy Products Co.

CONTROL KNOB

0

FSC-200

FSC-200

Advanced Thermal Solutions, Inc.

FAN SPEED CONTROLLER

0

C-820

C-820

REED Instruments

SOFT CARRYING CASE

2

PPX03V100

PPX03V100

Bartovation

PEROXIDE TEST STRIPS, 0-400 PPM

100

4112875

4112875

Fluke Electronics

GOLDCAREPLAN-GROUP4-5YR

0

C116

C116

Fluke Electronics

CARRYING CASE POLYESTER BLK/YEL

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top