Accessories

Image Part Number Description / PDF Quantity Rfq
71S170-C10S3

71S170-C10S3

Rosenberger

BNC 75 OHM CALIBRATION LOAD

0

72-166-0

72-166-0

NTE Electronics, Inc.

BLK INSULATOR FOR 72-167/168

436

VS-AVT-CABLE-30

VS-AVT-CABLE-30

Panduit Corporation

VERISAFE REPLACEMENT AVT SYSTEM

410

ASTM 3 - 10G

ASTM 3 - 10G

Adam Equipment

ASTM WEIGHTS

50

PK007-024

PK007-024

Teledyne LeCroy

GROUND LEAD 0.8MM SOCKET

2

BP-8

BP-8

DGH Corporation

MOUNTING BOARD, 8 MODULE, RS-485

3

RM50A

RM50A

AIMtti

2U RACK MOUNT FOR BENCH INSTRUME

0

ASTM 1 - 500G

ASTM 1 - 500G

Adam Equipment

ASTM WEIGHTS

50

BU-62-4

BU-62-4

Mueller Electric Co.

INSULATOR-ALLIGATOR CLIP PVC YEL

7069372

R9950

R9950

REED Instruments

LARGE CARRYING CASE

125

CT3273

CT3273

Cal Test Electronics

WALL LEADS RACK - 50 LEADS

24

72904-2

72904-2

Pomona Electronics

CLIP LEAD FOR MICRO GRABBER RED

0

MS-POE-WM

MS-POE-WM

Fluke Networks

MICROSCANNER POE WIREMAP ADAPT

2

CT4122

CT4122

Cal Test Electronics

USB POWER LEAD 200CM 2.1MM +P

6

JP-8681-4

JP-8681-4

Mueller Electric Co.

INSULATED BOOT

1955

183283-02

183283-02

NI

RS485 NULL-MODEM CABLE, DB-9 FEM

5

R9060

R9060

REED Instruments

5-STEP CALIBRATION BLOCK

51

BU-72-6

BU-72-6

Mueller Electric Co.

INSULATOR

11165

VC221B

VC221B

Amprobe

VINYL CASE FULL SIZE METERS

0

05S121-K20S3

05S121-K20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email