Accessories

Image Part Number Description / PDF Quantity Rfq
71K170-C10S3

71K170-C10S3

Rosenberger

BNC 75 OHM CALIBRATION LOAD

0

72-179-0

72-179-0

NTE Electronics, Inc.

4MM SHROUDED BANANA PLUG/BLACK

1504

2200M

2200M

3M

7000 SOFT CARRYING BAG

0

19K121-K20D3

19K121-K20D3

Rosenberger

SMP CALIBRATION ADAPTER

0

PKXX0-SI

PKXX0-SI

Teledyne LeCroy

TIP RETAINING CLIP

0

PK1-5MM-116

PK1-5MM-116

Teledyne LeCroy

FLXBL ADPT 5.0 TO 2MM BANANA PLG

3

05S160-S50D3

05S160-S50D3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

PK-ZS-009

PK-ZS-009

Teledyne LeCroy

COPPER TAPE PAD 4/PC

28

64S121-K20S3

64S121-K20S3

Rosenberger

4.3/10 CALIBRATION ADAPTER

0

72-147

72-147

NTE Electronics, Inc.

GROUNDING CLAMP STEEL

574

PKIT2-5MM-101

PKIT2-5MM-101

Teledyne LeCroy

ACCY KIT - PP010

4

72-064

72-064

NTE Electronics, Inc.

4MM RIGHT ANGLE PLUG RED

44

05K160-K50D3

05K160-K50D3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

PKIT4-5MM-101

PKIT4-5MM-101

Teledyne LeCroy

PROBE REPLACEMENT KIT

10

72-082

72-082

NTE Electronics, Inc.

MULTI PIN PAIR SPARE PINS

3

RK153

RK153

B&K Precision

BRACKETED RACK MOUNT KIT (FOR MD

13

03K30R-MSOTS3

03K30R-MSOTS3

Rosenberger

PRECISION 3.5 CALIBRATION KIT

0

72-146-2

72-146-2

NTE Electronics, Inc.

RED INSULATOR FOR 72-144/145

699

CT2714

CT2714

Cal Test Electronics

PROBE TIP GROUND NI. PLT. 5MM

0

ADPTR-GU10

ADPTR-GU10

Amprobe

LIGHT-CHK ADAPTER GU10

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top