Accessories

Image Part Number Description / PDF Quantity Rfq
01K101-K20D3

01K101-K20D3

Rosenberger

PRECISION 1.00 CALIBRATION ADAPT

0

SDS2000X-4BW02

SDS2000X-4BW02

Siglent Technologies

BANDWIDTH UPGRADE, 100 TO 200 MH

4

VL1735/45

VL1735/45

Fluke Electronics

BANANA 4-PHASE VOLTAGE LEAD SET

0

HVFO100-1X-TIP-U

HVFO100-1X-TIP-U

Teledyne LeCroy

OSCOPE PROBE X1 60MHZ 1M

2

TMPCNS05

TMPCNS05

Red Lion

QUICK DISCONNECT STANDARD CONN

4

LP104

LP104

Comet America

ADAPTER FOR CO2 ADJUSTMENT

20

72-146-9

72-146-9

NTE Electronics, Inc.

WHT INSULATOR FOR 72-144/145

636

LP103

LP103

Comet America

MAGNETIC HOLDER GSM

20

19S121-S20D3

19S121-S20D3

Rosenberger

SMP CALIBRATION ADAPTER

0

ASTM 4 1G - 500G CALIBRATION WEIGHT SET

ASTM 4 1G - 500G CALIBRATION WEIGHT SET

Adam Equipment

ASTM WEIGHT SETS

50

SVA1000X-EMI

SVA1000X-EMI

Siglent Technologies

EMI ACTIVATION LICENSE (SVA1000X

4

MP041

MP041

Comet America

FOUR RUBBER FEET FOR MS6R

20

PK-ZS-023

PK-ZS-023

Teledyne LeCroy

STRAIGHT PIN ZS4000 4/PC

1

CTM-23-0

CTM-23-0

Cal Test Electronics

MED HEAVY DUTY CLIP INSULATOR VI

166

119S12L-000D3

119S12L-000D3

Rosenberger

PSMP OPEN

0

69409

69409

Klein Tools

LINE SPLITTER 10X

23

M1034

M1034

Comet America

JG MODULE FOR MS DATALOGGER RTD

20

M1044

M1044

Comet America

CTU COUNTER LOGGER MS

20

4112990

4112990

Fluke Electronics

GOLDCAREPLAN-GROUP6-2-7YR

0

PGE05V100

PGE05V100

Bartovation

N-PROPYLTHIOURACIL TEST PAPER FO

100

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments