Accessories

Image Part Number Description / PDF Quantity Rfq
73040

73040

Pomona Electronics

OSCILLOSCOPE PROBE ACCY KIT

7

FLUKE-CV401

FLUKE-CV401

Fluke Electronics

4" IR WINDOW KEY DOOR LATCH

3

C550

C550

Fluke Electronics

BAG TOOL STEEL REINFORCED FRAME

2

VDV512-110

VDV512-110

Klein Tools

COAX EXPLORER 2 REMOTE KIT

16

MP012

MP012

Comet America

HOLDER FOR DATA LOGGER

20

779556-01

779556-01

NI

BNC-2090A RACK-MOUNTABLE ACCESSO

10

CL205

CL205

FLIR Extech

EXSTIK CHLORINE ELECTRODE

0

M1040

M1040

Comet America

QG INPUT MODULE FOR LOGGER MS

20

PK007-003

PK007-003

Teledyne LeCroy

ADJUSTMENT TOOL

1

BU-29-6

BU-29-6

Mueller Electric Co.

INSUL GEOPHONE PVC BLUE 3.5"

46824

TMWSJ025

TMWSJ025

Red Lion

THERMO WIRE TYPE J 25 FT 24 AWG

6

4112882

4112882

Fluke Electronics

SILVERCAREPLAN-GROUP4-3YR

0

06K121-K20S3

06K121-K20S3

Rosenberger

PRECISION TNC CALIBRATION ADAPTO

0

PT300

PT300

FLIR Extech

PRESSURE TRANSDUCER, 300 PSI

0

BU-36-2

BU-36-2

Mueller Electric Co.

INSULATOR FOR BU-34,34C SRS RED

22151000

VS-AVT-RKP2

VS-AVT-RKP2

Panduit Corporation

COMPLETE KIT TO RETROFIT EQUIPME

16

TPI A103

TPI A103

TPI (Test Products International)

BOOT HOOK FOR TPI DMM'S

0

VS-CKP4-000

VS-CKP4-000

Panduit Corporation

VERISAFE INSULATION PIERCING CON

10

CBL-S2

CBL-S2

AIMtti

SERIAL CABLE FOR HA1600 LCR400 A

0

PSA-CK

PSA-CK

AIMtti

CABLE AND CONNECTOR KIT PSA

0

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top