Accessories

Image Part Number Description / PDF Quantity Rfq
M1028

M1028

Comet America

B2GINPUT MOD,MS LOGGER 0-5A

20

M1015

M1015

Comet America

E2 INPUT 0-10V, ISOLATED

20

182482-01

182482-01

NI

CABLE ASSY KIT,68-68,SCSI-II,IDC

7

C125

C125

Fluke Electronics

COMPACT SOFT CASE 120 SERIES

7

M1020

M1020

Comet America

K1 MOD. FOR MS RTD SENSOR PT1000

20

RPM80

RPM80

Fluke Electronics

INDUCTIVE PICK-UP

0

HDO4K-UART-RS232BUS TD

HDO4K-UART-RS232BUS TD

Teledyne LeCroy

UART RS232 TRIGGER DECODE OPTION

0

1404-XR

1404-XR

3M

EMS 4" EXTENDED RANGE 5' BALL MA

54

RD-AAA

RD-AAA

Seek Thermal

METAL D-RING WITH SCREWS FOR REV

12

PP005-GLPT

PP005-GLPT

Teledyne LeCroy

PROBE TIP GND LEAD

38

DMSC-9U

DMSC-9U

Paladin Tools (Greenlee Communications)

INTERFACE KIT USB

0

CT3823-0

CT3823-0

Cal Test Electronics

REPLACEMENT TIP HIGHVOLTAGE THRE

82

HDO4K-LINBUS TD

HDO4K-LINBUS TD

Teledyne LeCroy

LIN TRIGGER DECODE OPTION

0

TAS90

TAS90

Fluke Electronics

SHIELDED TEST LEAD ACC. SET

0

BU-72-0

BU-72-0

Mueller Electric Co.

INSULATOR-ALLIGATOR CLIP PVC BLK

10

4112745

4112745

Fluke Electronics

GOLDCAREPLAN-GROUP2-4YR

0

69146

69146

Klein Tools

ADAPTER FROM TYPE K TO BANANA PL

0

RKPVS

RKPVS

B&K Precision

PVS RACKMOUNT KIT

1

CT3677

CT3677

Cal Test Electronics

IC LEAD COMB KIT RED 0.5MM 12 PC

4

RK3U

RK3U

B&K Precision

RACKMOUNT KIT FOR 9832 AND 9833

2

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email