Accessories

Image Part Number Description / PDF Quantity Rfq
SSA3000XR-AMK

SSA3000XR-AMK

Siglent Technologies

ADVANCED MEASUREMENT ACTIVATION

4

SDG-6000X-IQ

SDG-6000X-IQ

Siglent Technologies

SDG-6000X IQ SIGNAL GENERATOR FU

4

05K165-K20S3

05K165-K20S3

Rosenberger

PRECISION N TYPE CALIBRATION ADA

0

06S150-C10S3

06S150-C10S3

Rosenberger

PRECISION TNC CALIBRATION LOAD

0

72-157-9

72-157-9

NTE Electronics, Inc.

WHITE INSULATOR FOR 72-148/149/1

496

2629

2629

Fluke Electronics

CABLE 50 FT. EXTENSION 1620-X

0

09K12S-000S3

09K12S-000S3

Rosenberger

PRECISION 2.40 SHORT

0

4112983

4112983

Fluke Electronics

GOLDCAREPLAN-GROUP6-2-7YR

0

CT3976

CT3976

Cal Test Electronics

PROBE BODY FIXED TIP, W/SPRING H

5

05S30R-MSOS3

05S30R-MSOS3

Rosenberger

PRECISION N TYPE CALIBRATION KIT

0

183045-01

183045-01

NI

RS232 STRAIGHT-THROUGH CABLE, DB

5

DX20-SP

DX20-SP

Teledyne LeCroy

SP TEST LEAD SET

2

322100013

322100013

Seeed

RF EXPLORER PROTECTION BOOT (BLU

0

183045-02

183045-02

NI

RS232 STRAIGHT-THROUGH CABLE, DB

5

1508/POM

1508/POM

Pomona Electronics

HOLDER TEST LEAD WIRES .210" DIA

281

72-157-4

72-157-4

NTE Electronics, Inc.

YELLOW INSULATOR 72-148/149/153/

181

19K12L-000D3

19K12L-000D3

Rosenberger

SMP OPEN

0

H6

H6

Fluke Electronics

HOLSTER INFRARED THERMOMETER

0

4112777

4112777

Fluke Electronics

SILVERCAREPLAN-GROUP2-4YR

0

BP120MH

BP120MH

Fluke Electronics

RECHARGEABLE BATTERY PACK

5

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top