Accessories

Image Part Number Description / PDF Quantity Rfq
PCL04V100

PCL04V100

Bartovation

RESTAURANT CHLORINE SANITIZER PL

100

72-165-2

72-165-2

NTE Electronics, Inc.

RED INSULATOR FOR 72-163/164

944

R4700SD-PROBE

R4700SD-PROBE

REED Instruments

REPLACEMENT MULTI-FUNCTION PROBE

2

HDO4K-ARINC429BUS DSYMBOLIC

HDO4K-ARINC429BUS DSYMBOLIC

Teledyne LeCroy

ARINC 429 SYMBOLIC DECODE OPTION

0

119S150-C10D3

119S150-C10D3

Rosenberger

PSMP CALIBRATION LOAD

0

G1009

G1009

Mark-10

COMPRESSION PLATE, 2 DIA., #10-3

9

82-2 ORN

82-2 ORN

E-Z-Hook

CLAMP WIRE INSUL PIERC ORANGE

27

M1041

M1041

Comet America

S INPUT MODULE FOR DATALOGGER MS

20

G1061

G1061

Mark-10

WEDGE GRIP, 0.75 JAW WIDTH, 5/16

8

AI-000505-120

AI-000505-120

Mueller Electric Co.

120" GROUND SS CABLE NO CLIPS

623

VDV999-059

VDV999-059

Klein Tools

TRACEALL PROBE TIP

12

M1039

M1039

Comet America

PG INPUT MODULE FOR LOGGER MS

20

SP009

SP009

Comet America

WALL HOLDER DIGIL

20

ASTM 4 1G - 200G CALIBRATION WEIGHT SET

ASTM 4 1G - 200G CALIBRATION WEIGHT SET

Adam Equipment

ASTM WEIGHT SETS

49

R1420

R1420

REED Instruments

ELECTRODE STORAGE SOLUTION

22

M1055

M1055

Comet America

D4 INPUT 0-75V

20

CT3041

CT3041

Cal Test Electronics

TRI-FOLD ACCESSORY POUCH, BLACK

6

782536-01

782536-01

NI

SCB-68A SHIELDED CONNECTOR BLK

22

PK006-1

PK006-1

Teledyne LeCroy

RPLCMNT DUAL LEAD ADAPT

6

1256

1256

3M

EMS MINI-MARKER POWER

50

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top