Accessories

Image Part Number Description / PDF Quantity Rfq
MO290-EP

MO290-EP

FLIR Extech

EXTENSION PROBE WITH 30" CABLE

0

CABLE REEL 50M RD

CABLE REEL 50M RD

Fluke Electronics

FLUKE-1623-2/1625-2 50M RED

0

PK106-1

PK106-1

Teledyne LeCroy

DUAL LEAD ADAPT PP005/PPE

13

900B

900B

Tempo Communications

CASE CARRY-HARD 3X HH

1

VS-AVT-RKP1

VS-AVT-RKP1

Panduit Corporation

COMPLETE KIT TO RETROFIT EQUIPME

1181

EL-WIFI WALL BRACKET

EL-WIFI WALL BRACKET

Lascar Electronics

WALL MOUNT BRACKET

10

PGA05V50

PGA05V50

Bartovation

4 PAD COBALT CHLORIDE HUMIDITY T

93

WS3K-EMB

WS3K-EMB

Teledyne LeCroy

EMBEDDED SOFTWARE OPTION FOR WS3

0

MP020

MP020

Comet America

DIN RAIL 35 MM FOR OUTPUT RELAYS

20

BU-46PR-2

BU-46PR-2

Mueller Electric Co.

SLEEVE INSULATOR PAIR BU-46 RED

1248

03S30R-MSOS3

03S30R-MSOS3

Rosenberger

PRECISION 3.5 CALIBRATION KIT

0

PPX02V100

PPX02V100

Bartovation

PEROXIDE TEST STRIPS, LOW LEVEL,

100

SDS2000-RMK

SDS2000-RMK

Siglent Technologies

RACK MOUNT KIT (SDS2000/2000X SE

1

M1009

M1009

Comet America

D0 INPUT 0-100MV

20

80-16-S10

80-16-S10

E-Z-Hook

NAIL HARNESS .125DIA 3.0" PKG10

0

80PJ-EXT

80PJ-EXT

Fluke Electronics

KIT EXTENSION WIRE THERMOCOUPLE

0

1402-XR

1402-XR

3M

EMS 4" EXTENDED RANGE 5' BALL MA

11

PPX01V50

PPX01V50

Bartovation

VERY HIGH LEVEL PEROXIDE TEST ST

100

ES30

ES30

Mark-10

TEST STAND, HAND WHEEL-OPERATED,

1

180524-05

180524-05

NI

CABLE ASSY,50P,FLAT,NB1,.5M

5

Accessories

1. Overview

Test and Measurement Accessories (TMA) are peripheral devices used to enhance the functionality, accuracy, and safety of measurement systems. These components enable signal transmission, environmental adaptation, and physical interfacing between test equipment and devices under test (DUT). Their importance in modern technology spans across R&D, quality control, and field diagnostics, ensuring reliable data acquisition in electronics, telecommunications, and industrial systems.

2. Major Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
ProbesSignal acquisition with high impedance and bandwidthOscilloscope probes for circuit debugging
SensorsConvert physical quantities to electrical signalsTemperature sensors in environmental monitoring
Cables and AdaptersEnsure low-loss signal transmissionRF cables for 5G network testing
Load BanksSimulate electrical loads for system validationPower supply stress testing in data centers
Optical AttenuatorsControl light signal strength in fiber opticsTelecom network signal balancing

3. Structure and Components

Typical TMA configurations include: - Probe assemblies: Tip contact points, coaxial shielding, and connector interfaces (e.g., SMA, BNC) - Sensor modules: Sensing elements (e.g., thermocouples, strain gauges), signal conditioning circuits, and protective housings - Interconnect systems: Multi-layer dielectric materials with impedance-controlled conductors - Calibration hardware: Precision resistors, reference voltage sources, and traceable measurement standards

4. Key Technical Specifications

ParameterDescriptionImportance
Frequency RangeOperational bandwidth (DC-40GHz)Determines signal fidelity for high-speed measurements
Accuracy ClassMeasurement error tolerance ( 0.01% to 1%)Critical for compliance testing in medical devices
Impedance Matching50 /75 standardizationMinimizes signal reflection in RF systems
Environmental RatingIP67, temperature range (-40 C to +150 C)Ensures reliability in harsh industrial conditions
Dynamic RangeSignal amplitude capability (e.g., -100dBm to +30dBm)Essential for wireless communication testing

5. Application Fields

Major industries include: - Electronics manufacturing: PCB testing with flying probe testers - Telecommunications: 5G base station RF analysis - Medical devices: ECG machine calibration - Energy systems: Solar inverter efficiency monitoring - Automotive: CAN bus signal integrity verification

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Keysight TechnologiesN2890A Differential Probe1GHz bandwidth, 100:1 attenuation ratio
TektronixP5200A High-Voltage Probe200MHz, 1000V measurement capability
Fluke Calibration729 Pressure ControllerAutomatic pressure control with 0.01% accuracy
Rohde & SchwarzSMA100B Signal Source10MHz-44GHz frequency range for lab use

7. Selection Guidelines

Key considerations: - Compatibility: Match connector types and impedance with test equipment - Environmental factors: Consider temperature, humidity, and vibration resistance - Measurement resolution: Select accuracy class based on application standards (e.g., ISO 17025) - Cost-efficiency: Balance precision requirements with budget constraints - Calibration support: Verify availability of NIST/ISO traceable certification

8. Industry Trends

Emerging developments: - Smart accessories: Integrated IoT-enabled probes with real-time data logging - High-frequency solutions: Development for 6G testing beyond 100GHz - Miniaturization: Chip-scale sensors for embedded system testing - Software integration: API-enabled accessories for automated test systems - Energy efficiency: Low-power consumption designs for portable field instruments

RFQ BOM Call Skype Email
Top