Inrush Current Limiters (ICL)

Image Part Number Description / PDF Quantity Rfq
SL22 7R010

SL22 7R010

Ametherm

ICL 7 OHM 20% 10A 22MM

0

SG336

SG336

Ametherm

ICL 7 OHM 15% 10A 24.13MM

0

SL10 10004

SL10 10004

Ametherm

ICL 10 OHM 20% 4A 10MM

382

MS32 5R020

MS32 5R020

Ametherm

ICL 5 OHM 25% 20A 31MM

407

MS22 30005

MS22 30005

Ametherm

ICL 30 OHM 15% 5A 23MM

0

SL12 80002-B

SL12 80002-B

Ametherm

ICL 80 OHM 20% 2A 13MM

0

SL12 15004

SL12 15004

Ametherm

ICL 15 OHM 15% 4A 13MM

0

SG170

SG170

Ametherm

ICL 4 OHM 15% 8A 15.24MM

0

SL22 2R515-BT

SL22 2R515-BT

Ametherm

ICL 2.5 OHM 20% 15A 22MM

0

SL12 25003

SL12 25003

Ametherm

ICL 25 OHM 15% 3A 13MM

132

SG190

SG190

Ametherm

ICL 5 OHM 15% 4A 15.24MM

134

AS35 1R040

AS35 1R040

Ametherm

ICL 1 OHM 25% 40A 36MM

20

SL32 4R023

SL32 4R023

Ametherm

ICL 4 OHM 20% 23A 31MM

9714

AS32 10015

AS32 10015

Ametherm

ICL 10 OHM 25% 15A 30MM

695

SL15 47003

SL15 47003

Ametherm

ICL 47 OHM 20% 3A 16MM

326

SL22 2R510-A

SL22 2R510-A

Ametherm

ICL 2.5 OHM 20% 10A 22MM

0

SL12 1R010-A

SL12 1R010-A

Ametherm

ICL 1 OHM 20% 10A 13MM

0

SL08 10002-A

SL08 10002-A

Ametherm

ICL 10 OHM 20% 2A 8MM

7851

SL15 22102

SL15 22102

Ametherm

ICL 220 OHM 25% 2A 16MM

0

SL08 5R002

SL08 5R002

Ametherm

ICL 5 OHM 20% 2A 8MM

6904

Inrush Current Limiters (ICL)

1. Overview

Inrush Current Limiters (ICL) are electronic components designed to suppress peak currents during device startup, protecting circuits from thermal and electrical stress. These transient currents, often 10-100 times higher than steady-state levels, occur in capacitive or inductive loads like power supplies, motors, and transformers. Modern electronics increasingly rely on ICLs to ensure system reliability, comply with safety standards, and extend product lifespans.

2. Main Types & Functional Classification

TypeFunctional CharacteristicsApplication Examples
NTC Thermistor ICLResistance decreases with temperature rise, self-resetting capabilitySwitching power supplies, LED drivers
PTC Thermistor ICLResistance increases with temperature, latching protectionMotor start circuits, battery management systems
Active ICLElectronic control using MOSFETs/IGBTs with precise timingHigh-precision industrial equipment
Hybrid ICLCombines passive and active elements for optimized performanceElectric vehicle charging stations

3. Structure & Composition

ICLs typically consist of three key elements:

  • Sensing Element: Thermally responsive material (e.g., NTC ceramic) or semiconductor junctions
  • Conductive Path: Silver/palladium electrodes in thermistors or MOSFET channels in active devices
  • Encapsulation: Epoxy or ceramic coatings for environmental protection

Active ICLs additionally integrate control ICs, gate drivers, and heat dissipation structures.

4. Key Technical Specifications

ParameterDescriptionImportance
Maximum Steady-State Current (Imax)Rated operational current after inrush suppressionDetermines continuous load capacity
Response Time (tresponse)Time to activate current limiting functionProtects against fast transient events
Clamping Voltage (Vclamp)Maximum voltage during limiting operationPrevents downstream component damage
Operating Temperature RangeFunctional temperature limitsEnsures reliability in extreme environments
Energy Absorption (I t)Total energy handling capabilityDefines survival under fault conditions

5. Application Fields

Major industries utilizing ICLs include:

  • Consumer Electronics: Power adapters, HVAC systems
  • Industrial: Variable frequency drives, welding machines
  • Automotive: EV charging stations, onboard chargers
  • Medical: MRI power systems, patient monitors

Typical case: NTC ICLs reduce 50A startup surges to 5A in 500W switching power supplies.

6. Leading Manufacturers & Products

ManufacturerProduct SeriesKey Features
TDK CorporationB59xxx SeriesHigh-reliability NTCs for automotive applications
LittelfusePTCLxxx SeriesAEC-Q100 qualified PTC devices
Bel Fuse0Zxxx SeriesMulti-layer ceramic thermistors
EPCOS (TDK)B25xxx SeriesHybrid ICLs with integrated sensors

7. Selection Guidelines

Critical factors for proper ICL selection:

  • Match Imax with system steady-state requirements (+20% margin)
  • Verify Vrated exceeds peak AC voltage by 50%
  • Consider ambient temperature effects on performance
  • Evaluate reset time for thermistor-based solutions
  • For active ICLs: Confirm compatibility with control signals

Example: A 240VAC motor drive requires an ICL with 15A Imax and 300Vclamp.

8. Industry Trends

Emerging developments include:

  • Miniaturization: 0603-sized active ICLs for mobile devices
  • Wide bandgap integration: SiC/GaN-based hybrid devices
  • Smart ICLs: Embedded current monitoring and diagnostics
  • Material innovation: Graphene-enhanced thermistors

Market growth driven by EV charging infrastructure and renewable energy systems, projected at 7.2% CAGR through 2027.

RFQ BOM Call Skype Email